Vika oxygen generator
Vika or TGK is an oxygen generating system for spaceflight. It is a SFOG, or solid-fuel oxygen generator, a kind of chemical oxygen generator. It has been used on the retired Mir space station and the International Space Station.
Vika oxygen generator
- Field
- solid-fuel oxygen generator
VALÉORINE Encyclopedia
VALÉORINE documentary reading
Documentary summary
Vika or TGK is an oxygen generating system for spaceflight. It is a SFOG, or solid-fuel oxygen generator, a kind of chemical oxygen generator. It has been used on the retired Mir space station and the International Space Station.
Admitted source layer · organised and presented by VALÉORINE
Note VALÉORINE
No house-authored Note is published until its assertions and sources pass the VALÉORINE evidence contract. The documentary article remains available in full while that enrichment is being consolidated.
Documentary enrichment in progress · no unsupported statement published
Reference Check
Propose documentary evidence for Vika oxygen generator. A contribution is never written directly as fact: identity, source, rights and evidence gates still decide.
Sign in to contribute
Documentary evidence
Evidence Panel
wikipedia incomplete · checked 25 September 2026
- Identity
- resolved
- Independent source families
- 0
- Admitted assertions
- 0
- Open conflicts
- 0
Authority files
wikidata · Q7929375 · wikipedia · Vika oxygen generator
In this article
Vika on Mir
Vika on Mir
It was originally developed by Roscosmos to supplement the Elektron oxygen system on Mir. A Vika module, also known as a "candle", contains about one liter of lithium perchlorate and can provide oxygen for one person for 24 hours. After being adopted for use on the ISS, it had the NASA name SFOG, but they also sometimes use the Russian acronym TGK.
• Illustration — Astronaut Jerry Linenger wearing a respirator mask following the 1997 fire aboard Mir from an SFOG fire Vika was used on Mir when more than three people were on board. Vika needs a supply of canisters to work, which must be flown into space. An example of this is Progress M-34, which carried 60 canisters to Mir in 1997 along with other cargo. If Vika and Elektron stopped working, the station would have to rely on a limited supply of bottled oxygen. In February 1997 a Vika chemical oxygen generator failed on Mir in the Kvant-1 module. It caught fire and spewed a torch-like jet of a molten metal and sparks across one of the Mir space station modules, burning for around 14 minutes and blocking the escape route to the docked Soyuz spacecraft. The fire was eventually extinguished, and the crew was not harmed. A definitive cause of the accident was not determined because the fire destroyed the device. It was suspected that a torn piece of rubber glove worn during assembly likely contaminated the canister. Despite this incident, NASA decided it was still the best supplemental oxygen system available, and supported its use on the then-upcoming ISS. The US and Russia worked together to improve the safety of the system before using it on the new space station.
Vika on ISS
Vika on ISS
A backup to the temperamental Elektron system used on both the ISS and Mir is the Vika solid-fuel oxygen generator (SFOG), which contains a replaceable cartridge – a thin-walled steel tube with a three-part block of oxygen-releasing mixture based on lithium perchlorate. Two parts are tablets of the chemical mixture and the third one is the igniter tablet with a flash igniter. The igniter is struck by a firing pin when the device is activated. One cartridge releases 600 L of oxygen and burns for 5–20 minutes at 450 -. The oxygen is cooled and filtered to remove dust and odours, and released into the space station atmosphere.
Primary material
Documents and archives
reference work
- “Vika oxygen generator”, English Wikipedia, consulted as further reading
Reputable secondary · Wikipedia
authority record
- Wikidata, structured authority record Q7929375: Vika oxygen generator
Unverified · Wikidata
Citations
References
Each reference names the institution holding it, so a reader may go to the document itself.
reference work
Partially resolvedauthority record
Unverified
The Encyclopedia exists whether or not anything is for sale. Corrections are recorded rather than overwritten, and every version of this record is kept. Published 14 August 2026.
Elsewhere in Scientific instruments
736 published records in this field, each with its sources named.
- vertical wind tunnelTerminology
- Very Long Baseline ArrayTerminology
- Very Small ArrayTerminology
- Víctor M. Blanco TelescopeTerminology
- Visible Infrared Imaging Radiometer SuiteTerminology
- Visible light communicationTerminology
- VISTATerminology
- Visual Monitoring CameraTerminology
Best supported in this field
For owners
Own an object connected with Vika oxygen generator?
A specialist will read what you send and tell you what the house can establish, what it cannot, and whether the object is suited to sale. There is no charge and no obligation. The object stays with you throughout; nothing is shipped to us unless it is arranged in writing beforehand.