nuclear clock
A nuclear clock or nuclear optical clock is an atomic clock which uses photons from a nuclear isomeric transition as its reference frequency, instead of the atomic electron transition energy used by conventional atomic clocks. Such a clock is expected to be more precise than the best current atomic clocks by a factor of about 10, with an achievable precision approaching the 10 −19 level. The only nuclear state suitable for the development of a nuclear clock using existing technology is thorium-229m, an isomer of thorium-229 and the lowest-energy nuclear isomer known.
Also recorded as nuclear optical clock
nuclear clock

LarsvdW · CC BY-SA 4.0
- Name
- Nuclear clock
- Field
- clock
Reference Check
Propose documentary evidence for nuclear clock. A contribution is never written directly as fact: identity, source, rights and evidence gates still decide.
Sign in to contribute
World of VALÉORINE
Documentary connections
Only confirmed graph relationships appear here. Images are shown only when their identity and reuse rights both pass the documentary gate.
Documentary evidence
Documentary basis
Authority files
wikidata · Q16040784 · wikipedia · Nuclear clock
In this article
Key facts
Key facts
• Name — Nuclear clock • Application — Timekeeping • Industry — Scientific, satellite navigation, and data transfer
Principle of operation
Principle of operation
Atomic clocks are today's most stable timekeeping devices. They operate by exploiting the fact that the gap between the energy levels of two bound electron states in an atom is constant across space and time. A bound electron can be excited with electromagnetic radiation precisely when the radiation's photon energy matches the energy of the transition. Via the Planck relation, that transition energy corresponds to a particular frequency. By irradiating an appropriately prepared collection of identical atoms and measuring the number of excitations induced, a light source's frequency can be tuned to maximize this response and therefore closely match the corresponding electron transition energy. The transition energy thus provides a standard of reference which can be used to calibrate such a source reliably. Conventional atomic clocks use microwave (high-frequency radio wave) frequencies around, but development of the laser has made it possible to generate very stable light frequencies, and the frequency comb makes it possible to count those oscillations (measured in hundreds of THz, meaning hundred of trillions of cycles per second) to extraordinarily high precision. A device which uses a laser in this way is known as an optical atomic clock. One prominent example of an optical atomic clock is the ytterbium (Yb) lattice clock, where a particular electron transition in the ytterbium-171 isotope is used for laser stabilization. In this case, experimenters stabilized a laser light to the corresponding electron transition, and found that the laser light at that point has frequency oscillations per second. Other examples for optical atomic clocks of the highest stability are the Yb-171 single-ion clock, the strontium(Sr)-87 optical lattice clock, and the aluminum(Al)-27 single-ion clock. These clocks achieve stabilities approaching, corresponding to about of drift over the 14-billion-year age of the universe. A nuclear optical clock uses the same principle of operation, except that the laser is calibrated against a nuclear transition instead of an atomic shell electron transition. The expected advantage of a nuclear clock is that the atomic nucleus is smaller than the atomic shell by up to five orders of magnitude, with correspondingly smaller magnetic dipole and electric quadrupole moments, and is therefore significantly less affected by external magnetic and electric fields. Such external perturbations are the limiting factor for the achieved stability of electron-based atomic clocks. Due to this fundamental advantage, a nuclear optical clock is expected to achieve a time stability approaching, a ten-fold improvement over electron-based clocks.
Ionization
Ionization
An excited atomic nucleus can shed its excess energy by two alternative paths: • radiatively, by direct photon (gamma ray) emission, or • by internal conversion, transferring the energy to a shell electron which is ejected from the atom. For most nuclear isomers, the available energy is sufficient to eject any electron, and the inner-shell electrons are the most frequently ejected. In the special case of, the energy is sufficient only to eject an outer electron (thorium's first ionization energy is), and if the atom is already ionized, there is not enough energy to eject a second (thorium's second ionization energy is). The two decay paths have different half-lives. Neutral decays almost exclusively by internal conversion, with a half-life of. In thorium cations, internal conversion is energetically prohibited, and is forced to take the slower path, decaying radiatively with a half-life of around half an hour. Thus, in the typical case that the clock is designed to measure radiated photons, it is necessary to hold the thorium in an ionized state. This can be done in an ion trap, or by embedding it in an ionic crystal with a band gap greater than the transition energy. In this case, the atoms are not 100% ionized, and a small amount of internal conversion is possible (reducing the half-life to approximately 10 minutes), but the loss is tolerable. Alternatively, the thorium can be embedded in a material with a bandgap less than the transition energy, and the resonance can be found by measuring the count of ejected electrons as a function of UV excitation wavelength. This method of interrogation has both benefits and disadvantages. The main drawback is that since the decay is much faster, the linewidth is greater, and the stability is limited to "only" about 1 part in. An advantage is that the readout is obtained by measuring ejected electrons, a common lab technique and one that is easy to miniaturize. Readout is also much faster due to the faster decay. Finally, only a very thin surface layer of thorium is required, potentially important as Th-229 is exceedingly rare the world supply is estimated at 40 grams.
Different nuclear clock concepts
Different nuclear clock concepts
Two different concepts for nuclear optical clocks have been discussed in the literature: trap-based nuclear clocks and solid-state nuclear clocks. As of 2026, only the latter has been constructed.
Trap-based nuclear clocks
Trap-based nuclear clocks
For a trap-based nuclear clock either a single 229 Th 3+ ion is trapped in a Paul trap, known as the single-ion nuclear clock, or a chain of multiple ions is trapped, considered as the multiple-ion nuclear clock. Such clocks are expected to achieve the highest time precision, as the ions are to a large extent isolated from their environment. A multiple-ion nuclear clock could have a significant advantage over the single-ion nuclear clock in terms of stability performance.
Solid-state nuclear clocks
Solid-state nuclear clocks
As the nucleus is largely unaffected by the atomic shell, it is practical to embed many nuclei into a crystal lattice environment. This is known as the crystal-lattice nuclear clock. Due to the high density of embedded nuclei, up to 10 18 per cm 3, this allows irradiating a huge number of nuclei in parallel, thereby drastically increasing the achievable signal-to-noise ratio, but at the cost of potentially higher external perturbations. It has also been proposed to irradiate a metallic 229 Th surface and to probe the isomer's excitation in the internal conversion channel, which is known as the internal-conversion nuclear clock. Both types of solid-state nuclear clocks were shown to offer the potential for comparable performance.
Transition requirements
Transition requirements
From the principle of operation of a nuclear optical clock, it is evident that direct laser excitation of a nuclear state is a central requirement for the development of such a clock. This is impossible for most nuclear transitions, as the typical energy range of nuclear transitions (keV to MeV) is orders of magnitude above the maximum energy which is accessible with significant intensity by today's narrow-bandwidth laser technology (a few eV). There are only two nuclear excited states known which possess a sufficiently low excitation energy (below 100 eV). These are • link, a metastable nuclear excited state of the isotope thorium-229 with an excitation energy of only about, and • link, a metastable excited state of uranium-235 with an energy of. However, has such an extraordinarily long radiative half-life (on the order of, 20,000 times the age of the universe, and far longer than its internal conversion half-life of 26 minutes) that it is not practical to use for a clock. This leaves only 229m Th with a realistic chance of direct nuclear laser excitation. Further requirements for the development of a nuclear clock are that • the lifetime of the nuclear excited state is relatively long, thereby leading to a resonance of narrow bandwidth (a high quality factor) and • the ground-state nucleus is easily available and sufficiently stable, to allow one to work with moderate quantities of the material. Fortunately, has a radiative half-life (time to decay to) of around, and has a half-life (time to decay to) of, fulfilling both conditions and making an ideal candidate for the development of a nuclear clock.
History of nuclear clocks
History of nuclear clocks
This section contains relevant developments OTHER than measurement of the Th-229m transition (e.g. energy and half-life) itself. It includes non-nuclear work on Th-229 atoms, such as laser trapping of ions. In 1996, Eugene V. Tkalya proposed the use of nuclear excitation as a "highly stable source of light for metrology". With the development (around 2000) of the frequency comb for measuring optical frequencies exactly, a nuclear optical clock based on was first proposed in 2003 by Ekkehard Peik and Christian Tamm, who developed an idea of Uwe Sterr. The paper contains both concepts, the single-ion nuclear clock, as well as the solid-state nuclear clock. In their pioneering work, Peik and Tamm proposed to use individual laser-cooled ions in a Paul trap to perform nuclear laser spectroscopy. Here the 3+ charge state is advantageous, as it possesses a shell structure suitable for direct laser cooling. It was further proposed to excite an electronic shell state, to achieve 'good' quantum numbers of the total system of the shell plus nucleus that will lead to a reduction of the influence induced by external perturbing fields. A central idea is to probe the successful laser excitation of the nuclear state via the hyperfine-structure shift induced into the electronic shell due to the different nuclear spins of ground- and excited state. This method is known as the double-resonance method. The expected performance of a single-ion nuclear clock was further investigated in 2012 by Corey Campbell et al. with the result that a systematic frequency uncertainty (precision) of the clock of could be achieved, which would be by about an order of magnitude better than the precision achieved by the best optical atomic clocks today. The nuclear clock approach proposed by Campbell et al. slightly differs from the original one proposed by Peik and Tamm. Instead of exciting an electronic shell state in order to obtain the highest insensitivity against external perturbing fields, the nuclear clock proposed by Campbell et al. uses a stretched pair of nuclear hyperfine states in the electronic ground-state configuration, which appears to be advantageous in terms of the achievable quality factor and an improved suppression of the quadratic Zeeman shift. In 2010, Eugene V. Tkalya showed that it was theoretically possible to use as a lasing medium to generate an ultraviolet laser. The solid-state nuclear clock approach was further developed in 2010 by W.G. Rellergert et al. with the result of an expected long-term precision of about. Although expected to be less precise than the single-ion nuclear clock approach due to line-broadening effects and temperature shifts in the crystal lattice environment, this approach may have advantages in terms of compactness, robustness and power consumption. The expected stability performance was investigated by G. Kazakov et al. in 2012. In 2020, the development of an internal conversion nuclear clock was proposed. Important steps on the road towards a nuclear clock include the successful direct laser cooling of ions in a Paul trap achieved in 2011, and a first detection of the isomer-induced hyperfine-structure shift, enabling the double-resonance method to probe a successful nuclear excitation in 2018.
History of 229m Th
History of 229m Th
Since 1976, the 229 Th nucleus has been known to possess a low energy excited state, whose excitation energy was originally shown to less than 100 eV, and then shown to be less than in 1990. This was, however, too broad an energy range to apply high-resolution spectroscopy techniques; the transition energy had to be narrowed down first. Initial efforts used the fact that, after the alpha decay of, the resultant nucleus is in an excited state and promptly emits a gamma ray to decay to either the base state or the metastable state. Measuring the small difference in the gamma-ray energies emitted in these processes allows the metastable state energy to be found by subtraction. However, nuclear experiments are not capable of finely measuring the difference in frequency between two high gamma-ray energies, so other experiments were needed. Because of the natural radioactive decay of 229 Th nuclei, a tightly concentrated laser frequency was required to excite enough nuclei in an experiment to outcompete the background radiation and give a more precise measurement of the excitation energy. Because it was infeasible to scan the entire 100eV range, an estimate of the correct frequency was needed. An early mis-step was the (incorrect) measurement of the energy value as 3.5±1.0 eV in 1994. This frequency of light is relatively easy to work with, so many direct detection experiments were attempted which had no hope of success because they were built of materials opaque to photons at the true, higher, energy. In particular: • thorium oxide is transparent to 3.5 eV photons, but opaque at 8.3 eV, • common optical lens and window materials such as fused quartz are opaque at energies above 8 eV, • molecular oxygen (air) is opaque to photons above; experiments must be conducted in a nitrogen or argon atmosphere, and • the ionization energy of thorium is so the nuclei will decay by internal conversion unless prevented (see Ionization). The energy value remained elusive until 2003, when the nuclear clock proposal triggered a multitude of experimental efforts to pin down the excited state's parameters like energy and half-life. The detection of light emitted in the direct decay of would significantly help to determine its energy to higher precision, but all efforts to observe the light emitted in the decay of were failing. The energy level was corrected to in 2007 (slightly revised to in 2009). Subsequent experiments continued to fail to observe any signal of light emitted in the direct decay, leading people to suspect the existence of a strong non-radiative decay channel. The detection of light emitted by the decay of 229m Th was reported in 2012, and again in 2018, but the observed signals were the subject of controversy within the community. A direct detection of electrons emitted by the isomer's internal conversion decay channel was achieved in 2016. This detection laid the foundation for the determination of the 229m Th half-life in neutral, surface-bound atoms in 2017 and a first laser-spectroscopic characterization in 2018. In 2019, the isomer's energy was measured via the detection of internal conversion electrons emitted in its direct ground-state decay to. Also a first successful excitation of the nuclear excited state of via synchrotron radiation was reported, enabling a clock transition energy measurement of. In 2020, an energy of was obtained from precision gamma-ray spectroscopy. Finally, precise measurements were achieved in 2023 by unambiguous detection of the emitted photons and in April 2024 by two reports of excitation with a tunable laser at and. The light frequency is now known with sufficient precision to enable future construction of a prototype clock, and determine the transition's exact frequency and its stability. Precision frequency measurements began immediately, with Jun Ye's laboratory at JILA making a direct comparison to a optical atomic clock. Published in September 2024, the frequency was measured as, a relative uncertainty of. This implies a wavelength of and an energy of. The work also resolved different nuclear quadrupole sublevels and measured the ratio of the ground and excited state nuclear quadrupole moment. Improvements will surely follow.
The first nuclear clocks
The first nuclear clocks
With the prerequisite research complete, attention shifted to the technical details of constructing a nuclear clock. The temperature sensitivity of solid-state nuclear clocks was studied, and it was found that one transition has a frequency minimum at. Since the first derivative vanishes at this point, this reduces the required temperature stability of a practical clock. The first two prototype nuclear clocks were announced in June 2026. Both use solid-state crystals of CaF 2 doped with. Their performance is so far similar to more mature atomic clock technologies (stability for intervals \tau up to 10,000 seconds about 3\cdot 10^{-12} \sqrt{\text{s}/\tau}, better than 4\cdot 10^{-12} \sqrt{\text{s}/\tau} for an HP 5071A/001 caesium atomic clock, but far worse than 1.55\cdot 10^{-13} \sqrt{\text{s}/\tau} for a caesium fountain), and development is expected to be rapid.
Applications
Applications
Solid-state nuclear clocks have the potential to make optical atomic clock performance available to applications which are currently precluded by the bulky atomic trapping systems, such as satellite-based navigation. The high performance of nuclear optical clocks will allow new applications inaccessible to other atomic clocks, such as relativistic geodesy, the search for topological dark matter, and the determination of time variations of fundamental constants. A nuclear clock has the potential to be particularly sensitive to possible time variations of the fine-structure constant. The central idea is that the low transition energy is due to a fortuitous cancellation between strong nuclear and electromagnetic effects within the nucleus, which are individually much stronger. Any variation of the fine-structure constant would affect the electromagnetic half of this balance, resulting in a proportionally very large change in the total transition energy. A change of even one part in 10 18 could be detected by comparison with a conventional atomic clock (whose frequency would also be altered, but not nearly as much), so this measurement would be extraordinarily sensitive to any potential variation of the constant. Recent measurements and analysis are consistent with enhancement factors on the order of 10 4.
Text attribution
Licensing
Text attribution
Part of the biographical narrative on this page reuses licensed material. Its origin, revision and licence are recorded here.
The biographical narrative on this page is based on the Wikipedia article Nuclear clock, revision 1370098340 (EN edition), by its contributors. VALÉORINE has edited that text and built its own documentary record around it. The reused material is available under CC BY-SA 4.0, and this page's reuse of it is offered under the same licence. Everything else on this page — the chronology, the holdings, the evidence, the plates and the connections — is VALÉORINE's own record. Sources and licences.
Notes from the source article
Cited by Wikipedia
Notes from the source article
These works are cited by the source article, in its own numbering. They are recorded as its citations, not as sources VALÉORINE has verified.
- 1.Peik, Ekkehard. Nuclear laser spectroscopy of the 3.5 eV transition in 229 Th. Europhysics Letters. 61. 2. 181–186. 15 January 2003. 10.1209/epl/i2003-00210-x.
- 2.Campbell, Corey. Single-ion nuclear clock for metrology at the 19th decimal place. Physical Review Letters. 108. 12. 23 March 2012. 10.1103/PhysRevLett.108.120802.
- 3.Thirolf, Peter. Shedding Light on the Thorium-229 Nuclear Clock Isomer. Physics. 17. April 29, 2024. 10.1103/Physics.17.71.
- 4.Tiedau, J. Laser Excitation of the Th-229 Nucleus. Physical Review Letters. 132. 18. 29 April 2024. 10.1103/PhysRevLett.132.182501.
- 5.Conover, Emily. A nuclear clock prototype hints at ultraprecise timekeeping. Science News. 5 September 2024.
- 6.von der Wense, Lars. The 229 Th isomer: prospects for a nuclear optical clock. The European Physical Journal A. 56. 11. 277. 2020-11-02. 1434-601X.
- 7.Miller, Johanna L. Slow-motion spectroscopy paves the way for a nuclear clock. Physics Today. 77. 6. 12–14. 1 June 2024. 10.1063/pt.kvtv.jxde.
- 8.Ludlow, Andrew D. Optical atomic clocks. Reviews of Modern Physics. 87. 2. 637–699. 26 June 2015. 10.1103/RevModPhys.87.637.
- 9.Atomic clock performance enabling geodesy below the centimetre level. Nature. 564. 7734. 87–90. 2018. 10.1038/s41586-018-0738-2.
- 10.Margolis, H. S. The CIPM list "Recommended values of standard frequencies": 2021 update. Metrologia. 61. 3. 25 January 2024. 10.1088/1681-7575/ad3afc.
- 11.International Bureau of Weights and Measures. Recommended Values of Standard Frequencies: Ytterbium 171 Atom (f ≈ 518 THz). 27 March 2026.
- 12.Huntemann, N. Single-ion atomic clock with 3×10 −18 systematic uncertainty. Phys. Rev. Lett. 116. 6. 8 February 2016. 10.1103/PhysRevLett.116.063001.
- 13.Nicholson, T. L. Systematic evaluation of an atomic clock at 2×10 −18 total uncertainty. Nature Communications. 6. 21 April 2015. 10.1038/ncomms7896.
- 14.Aeppli, Alexander. Clock with Systematic Uncertainty. Physical Review Letters. 133. 2. 15 March 2024. 10.1103/PhysRevLett.133.023401.
- 15.Erratum: 27 Al + quantum-logic clock with systematic uncertainty below 10 −18 [Physical Review Letters 123, 033201 (2019)]. Physical Review Letters. 131. 5. 1 August 2023. 10.1103/PhysRevLett.131.059901.
- 16.Radiative Decay of the 229m Th Nuclear Clock Isomer in Different Host Materials. Physical Review Research. 7. 15 January 2025. 10.1103/PhysRevResearch.7.013052.
- 17.Elwell, R. Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2. Nature. 648. 8093. 300–305. 2025. 10.1038/s41586-025-09776-4.
- 18.Performance of a 229 Thorium solid-state nuclear clock. New Journal of Physics. 14. 8. 2012. 10.1088/1367-2630/14/8/083019.
- 19.Constraining the evolution of the fundamental constants with a solid-state optical frequency reference based on the 229 Th nucleus. Physical Review Letters. 104. 20. 21 May 2010. 10.1103/PhysRevLett.104.200802.
- 20.von der Wense, L. Concepts for direct frequency-comb spectroscopy of 229m Th and an internal-conversion-based solid-state nuclear clock. Eur. Phys. J. D. 74. 7. 7 July 2020. 10.1140/epjd/e2020-100582-5.
- 21.Energy of the 229 Th nuclear clock transition. Nature. 573. 7773. 243–246. 2019. 10.1038/s41586-019-1533-4.
- 22.Measurement of the 229 Th isomer energy with a magnetic micro-calorimeter. Phys. Rev. Lett. 125. 14. 2020. 10.1103/PhysRevLett.125.142503.
- 23.Accurate measurement of the first excited nuclear state in 235 U. Phys. Rev. C. 97. 5. 2018. 10.1103/PhysRevC.97.054310.
- 24.Peik, E. Nuclear clocks for testing fundamental physics. Quantum Science and Technology. 6. 3. 15 April 2021. 10.1088/2058-9565/abe9c2.
- 25.Tkalya, Eugene V. Radiative lifetime and energy of the low-energy isomeric level in 229 Th. Phys. Rev. C. 92. 5. 2015. 10.1103/PhysRevC.92.054324.
- 26.Minkov, N. Reduced transition probabilities for the gamma decay of the 7.8 eV isomer in 229m Th. Physical Review Letters. 118. 21. 2017. 10.1103/PhysRevLett.118.212501.
- 27.Varga, Z. Determination of the 229 Th half-life. Phys. Rev. C. 89. 2014. 10.1103/PhysRevC.89.064310.
- 28.Tkalya, Eugene V. Processes of the nuclear isomer 229m Th(3/2 + , 3.5±1.0 eV) Resonant excitation by optical photons. Physica Scripta. 53. 3. 296–299. March 1996. 10.1088/0031-8949/53/3/003.
- 29.Tkayla, Eugene V. Proposal for a nuclear gamma-ray laser of optical range. Physical Review Letters. 106. 16. 3 November 2010. 10.1103/PhysRevLett.106.162501.
- 30.Zyga, Lisa. Proposed gamma-ray laser could emit 'nuclear light'. Phys.org. May 2, 2011.
- 31.Harris, David. Laser from Atomic Nuclei. Physical Review Focus. 27. April 22, 2011.
- 32.Campbell, C. J. Wigner crystals of 229 Th for optical excitation of the nuclear isomer. Physical Review Letters. 106. 22. 2 June 2011. 10.1103/PhysRevLett.106.223001.
- 33.Thielking, Johannes. Laser spectroscopic characterization of the nuclear-clock isomer 229m Th. Nature. 556. 7701. 321–325. 2018. 10.1038/s41586-018-0011-8.
- 34.Kroger, L. A. Features of the low energy level scheme of 229 Th as observed in the α decay of 233 U. Nucl. Phys. A. 259. 1. 29–60. 1976. 10.1016/0375-9474(76)90494-2.
- 35.Reich, C. W. Energy separation of the doublet of intrinsic states at the ground state of 229 Th. Phys. Rev. Lett. American Physical Society. 64. 3. 271–273. 15 January 1990. 10.1103/PhysRevLett.64.271.
- 36.Helmer, R. G. An Excited State of 229 Th at 3.5 eV. Phys. Rev. C. 49. 4. 1845–1858. 1994. 10.1103/PhysRevC.49.1845.
- 37.Heraeus. Fused Quartz and Fused Silica for Optical Applications: Data and Properties. 6. February 2023.
- 38.von der Wense, Lars. The 229 Th isomer: prospects for a nuclear optical clock. Eur. Phys. J. A. 56. 11. 1-58-->. 2 November 2020. 10.1140/epja/s10050-020-00263-0.
- 39.Energy splitting in the ground state doublet in the nucleus 229 Th. Phys. Rev. Lett. 98. 14. 2007. 10.1103/PhysRevLett.98.142501.
- 40.Improved value for the energy splitting of the ground-state doublet in the nucleus 229m Th. 15–19 June 2009.
- 41.Jeet, Justin. Results of a Direct Search Using Synchrotron Radiation for the Low-Energy 229 Th Nuclear Isomeric Transition. Physical Review Letters. 114. 25. 23 June 2015. 10.1103/physrevlett.114.253001.
- 42.Experimental search for the low-energy nuclear transition in 229 Th with undulator radiation. New Journal of Physics. 17. 5. 28 May 2015. 1367-2630.
- 43.von der Wense, Lars. On the direct detection of 229m Th. Ludwig-Maximilians-Universität München. 2016. 978-3-319-70461-6.
- 44.Stellmer, Simon. Attempt to optically excite the nuclear isomer in 229 Th. Phys. Rev. A. 97. 6. 18 June 2018. 10.1103/PhysRevA.97.062506.
- 45.Observation of the Deexcitation of the 229m Th Nuclear Isomer. Physical Review Letters. 109. 16. 2012. 0031-9007.
- 46.Borisyuk, P. V. Excitation of 229 Th nuclei in laser plasma: the energy and half-life of the low-lying isomeric state. 2018.
- 47.Peik, E. Comment on "Observation of the Deexcitation of the 229m Th Nuclear Isomer". Physical Review Letters. 111. 1. 2013. 10.1103/PhysRevLett.111.018901.
- 48.von der Wense, Lars. Direct detection of the 229 Th nuclear clock transition. Nature. 533. 7601. 47–51. 5 May 2016. 10.1038/nature17669.
- 49.Seiferle, Benedict. Lifetime measurement of the 229 Th nuclear isomer. Physical Review Letters. 118. 4. 26 January 2017. 10.1103/PhysRevLett.118.042501.
- 50.Masuda, Takahiko. X-ray pumping of the 229 Th nuclear clock isomer. Nature. 573. 7773. 238–242. 2019. 10.1038/s41586-019-1542-3.
- 51.Energy of the 229 Th nuclear clock isomer determined by absolute gamma-ray energy difference. Phys. Rev. Lett. 123. 22. 2019. 10.1103/PhysRevLett.123.222501.
- 52.Conover, Emily. Measurements of a key radioactive decay nudge a nuclear clock closer to reality. ScienceNews. June 1, 2023.
- 53.Kraemer, Sandro. Observation of the radiative decay of the 229 Th nuclear clock isomer. Nature. 617. 7962. 706–710. May 25, 2023. 10.1038/s41586-023-05894-z.
- 54.Elwell, R. Laser excitation of the 229 Th nuclear isomeric transition in a solid-state host. Physical Review Letters. 133. 1. 2 July 2024. 10.1103/PhysRevLett.133.013201.
- 55.Klapetz, Patrick. Thorium-229: Erstmals Atomkern mit Laser angeregt. Golem.de: IT-News für Profis. 2024-04-29.
- 56.Thoriumclock.eu project. We did it !. 29 April 2024.
- 57.Thirolf, Peter G. 'Phase Transition' in the 'Thorium-Isomer Story'. Acta Physica Polonica B. 51. 3. 561–570. March 2020. 10.5506/APhysPolB.51.561.
- 58.Gibney, Elizabeth. Best ever clocks: breakthrough paves way for ultra-precise 'nuclear' timekeepers. Nature. 629. 8012. 514–515. 8 May 2024. 10.1038/d41586-024-01353-5.
- 59.Conover, Emily. Physicists take a major step toward making a nuclear clock. ScienceNews. 4 April 2024.
- 60.Zhang, Chuankun. Frequency ratio of the 229m Th nuclear isomeric transition and the 87 Sr atomic clock. Nature. 633. 8028. 63–70. 4 September 2024. 10.1038/s41586-024-07839-6.
- 61.Conover, Emily. A nuclear clock prototype hints at ultraprecise timekeeping. ScienceNews. 4 September 2024.
- 62.NIST. Major leap for nuclear clock paves way for ultraprecise timekeeping. 4 September 2024.
- 63.Thoriumclock.eu project. The first ultra precised nuclear clock is built!. 4 September 2024.
- 64.Zhang, Chuankun. 229 ThF 4 thin films for solid-state nuclear clocks. Nature. 636. 603–608. 18 December 2024. 10.1038/s41586-024-08256-5.
- 65.Higgins, Jacob S. Temperature Sensitivity of a Thorium-229 Solid-State Nuclear Clock. Physical Review Letters. 134. 17 March 2025. 10.1103/PhysRevLett.134.113801.
- 66.Ooi, Tian. Frequency reproducibility of solid-state thorium-229 nuclear clocks. Nature. 650. 72–78. 28 January 2026. 10.1038/s41586-025-09999-5.
- 67.Jarman, Sam. Nuclear clocks tick for the first time. Phys.org. 12 June 2026.
- 68.Conover, Emily. Clocks made from an atomic nucleus just ticked on for the first time. ScienceNews. 11 June 2026.
- 69.Toscani De Col, Luca. A thorium-229 optical nuclear clock with feedback loop. 3 Jun 2026.
- 70.Huang, Beichen. A nuclear clock based on 229 Th. 7 Jun 2026.
- 71.HP Agilent 5071A Primary Frequency Standard (Cesium Beam): Measured Performance
- 72.Progress towards an accuracy evaluation of NIST-F4 cesium fountain clock
- 73.Conover, Emily. A nuclear clock prototype hints at ultraprecise timekeeping. ScienceNews. 4 September 2024.
- 74.Derevianko, A. Hunting for topological dark matter with atomic clocks. Nature Physics. 10. 12. 933–936. December 2014. 10.1038/nphys3137.
- 75.Thirolf, P. G. Improving Our Knowledge on the 229m Thorium Isomer: Toward a Test Bench for Time Variations of Fundamental Constants. Annalen der Physik. 531. 5. 2019. 10.1002/andp.201800381.
- 76.Enhanced Effect of Temporal Variation of the Fine Structure Constant and the Strong Interaction in 229m Th. Physical Review Letters. 97. 9. September 2006. 10.1103/PhysRevLett.97.092502.
- 77.Thirolf, Peter. From atomic to nuclear clocks. CERN Courier. 2022-09-05.
- 78.Howlett, Joseph. The First Nuclear Clock Will Test if Fundamental Constants Change. Quanta Magazine. 4 September 2024.
- 79.Fadeev, Pavel. Sensitivity of 229 Th nuclear clock transition to variation of the fine-structure constant. Physical Review A. 102. 5. November 2020. 10.1103/PhysRevA.102.052833.
- 80.Caputo, Andrea. Sensitivity of nuclear clocks to new physics. Physical Review C. 112. 3. 2025. 10.1103/l29n-gt5j.
- 81.Beeks, Kjeld. Fine-structure constant sensitivity of the Th-229 nuclear clock transition. 24 July 2024.
Bibliography printed in the source article · 1
- "The 229 Th isomer: prospects for a nuclear optical clock" (November 2020) European Physics Journal A.
References
Citations
References
Each reference names the institution holding it, so a reader may go to the document itself.
reference work
Secondary witnessreference work
Secondary witness
The Encyclopedia exists whether or not anything is for sale. Corrections are recorded rather than overwritten, and every version of this record is kept. Published 14 August 2026.
Elsewhere in Clocks
110 published records in this field, each with its sources named.
- Monstrance clockTerminology
- Myriad year clockTerminology
- National Timing CentreTerminology
- Nobel IceTerminology
- oil-lamp clockTerminology
- Olomouc Astronomical ClockTerminology
- Optical Lattice ClockTerminology
- Ottery St Mary astronomical clockTerminology
Best supported in this field
For owners
Own an object connected with nuclear clock?
A specialist will read what you send and tell you what the house can establish, what it cannot, and whether the object is suited to sale. There is no charge and no obligation. The object stays with you throughout; nothing is shipped to us unless it is arranged in writing beforehand.