atomic clock
Illustration — Simplified block diagram of a typical commercial caesium beam frequency reference • Illustration — NIST physicists Steve Jefferts (foreground) and Tom Heavner with the NIST-F2 caesium fountain atomic clock, a civilian time standard for the USA • Illustration — The master atomic clock ensemble at the U.S. Naval Observatory in Washington, D.C, which provides the time standard for the U.S. Department of Defense. The rack-mounted units in the background are HP 5071A caesium beam clocks. The black units in the foreground are Sigma-Tau MHM-2010 hydrogen maser standards.
atomic clock

NIST · NIST Unveils Chip-Scale Atomic Clock (archive) · Public domain
- Field
- clock
VALÉORINE Encyclopedia
VALÉORINE documentary reading
Documentary summary
Illustration — Simplified block diagram of a typical commercial caesium beam frequency reference • Illustration — NIST physicists Steve Jefferts (foreground) and Tom Heavner with the NIST-F2 caesium fountain atomic clock, a civilian time standard for the USA • Illustration — The master atomic clock ensemble at the U.S. Naval Observatory in Washington, D.C, which provides the time standard for the U.S. Department of Defense. The rack-mounted units in the background are HP 5071A caesium beam clocks. The black units in the foreground are Sigma-Tau MHM-2010 hydrogen maser standards.
Admitted source layer · organised and presented by VALÉORINE
Note VALÉORINE
No house-authored Note is published until its assertions and sources pass the VALÉORINE evidence contract. The documentary article remains available in full while that enrichment is being consolidated.
Documentary enrichment in progress · no unsupported statement published
Reference Check
Propose documentary evidence for atomic clock. A contribution is never written directly as fact: identity, source, rights and evidence gates still decide.
Sign in to contribute
Documentary evidence
Evidence Panel
not yet certified
- Identity
- resolved
- Independent source families
- 0
- Admitted assertions
- 0
- Open conflicts
- 0
Authority files
bnf · gnd · loc · wikidata · Q227467 · wikipedia · Atomic clock
In this article
Recent advances
Recent advances
An atomic clock is a clock that measures time by monitoring the resonant frequency of atoms. It is based on the fact that atoms have quantised energy levels, and transitions between such levels are driven by very specific frequencies of electromagnetic radiation. This phenomenon serves as the basis for the SI definition of the second: The second, symbol s, is the SI unit of time. It is defined by taking the fixed numerical value of the caesium frequency, \Delta \nu_\text{Cs}, the unperturbed ground-state hyperfine transition frequency of the caesium-133 atom, to be when expressed in the unit Hz, which is equal to s −1. This definition underpins the system of TAI, which is maintained by an ensemble of atomic clocks around the world. The system of UTC — the basis of civil time — implements leap seconds to allow clock time to stay within one second of Earth's rotation. The accurate time-keeping capabilities of atomic clocks are also used for navigation by satellite networks such as the EU’s Galileo Programme and the United States’ GPS. The timing accuracy of the atomic clocks matters because even a timing error of 1 nanosecond (10 −9 s) corresponds to a positional error of roughly 30 cm when multiplied by the speed of light. The main variety of atomic clock in use today employs caesium atoms (or ions) cooled to near absolute zero. For example, the United States’ primary standard, the NIST caesium fountain clock named NIST-F2, operates with a relative uncertainty around 10 −16.
In July 2025, researchers at the National Institute of Standards and Technology in the United States reported a record-setting optical atomic clock based on a trapped aluminium ion. This "quantum logic" clock achieves a systematic uncertainty corresponding to around 19 decimal places of accuracy, representing a 41% improvement over the previous record and being 2.6 times more stable than any other ion clock.
Redefinition of the second
Redefinition of the second
The rapid improvement in optical atomic clock performance has prompted the global time-and-frequency community to prepare for a possible redefinition of the SI second. In June 2025, a coordinated international comparison of optical clocks across six countries was reported — marking a major step towards establishing a global optical-time standard.
Technological impact
Technological impact
Optical atomic clocks are enabling new applications: ultra-precise time- and-frequency dissemination, improved global navigation satellite systems, relativistic geodesy (measuring differences in gravitational potential via clock rates), and tests of fundamental constants and general relativity.
History
History
• Illustration — Louis Essen (right) and Jack Parry (left) standing next to the world's first caesium-133 atomic clock in 1955, at the National Physical Laboratory in west London, England. The Scottish physicist James Clerk Maxwell proposed measuring time with the vibrations of light waves in his 1873 Treatise on Electricity and Magnetism: 'A more universal unit of time might be found by taking the periodic time of vibration of the particular kind of light whose wave length is the unit of length.' Maxwell argued this would be more accurate than the Earth's rotation, which defines the mean solar second for timekeeping. During the 1930s, the American physicist Isidor Isaac Rabi built equipment for atomic beam magnetic resonance frequency clocks. The accuracy of mechanical, electromechanical and quartz clocks is reduced by temperature fluctuations. This led to the idea of measuring the frequency of an atom's vibrations to keep time more accurately, as proposed by James Clerk Maxwell, Lord Kelvin, and Isidor Rabi. A prototype measuring phase transitions of the ammonia molecule was developed in 1949. The first practical atomic clock using caesium atoms was built at the National Physical Laboratory in the United Kingdom in 1955 by Louis Essen in collaboration with Jack Parry. • Illustration — A caesium atomic clock from 1975 (upper unit) and battery backup (lower unit) In 1949, Alfred Kastler and Jean Brossel developed a technique called optical pumping for electron energy level transitions in atoms using light. This technique is useful for creating much stronger magnetic resonance and microwave absorption signals. Unfortunately, this caused a side effect with a light shift of the resonant frequency. Claude Cohen-Tannoudji and others managed to reduce the light shifts to acceptable levels. Ramsey developed a method, now commonly known as Ramsey interferometry, for higher frequencies and narrower resonances in the oscillating fields. Kolsky, Phipps, Ramsey, and Silsbee used this technique for molecular beam spectroscopy in 1950. After 1956, atomic clocks were studied by many groups, such as the National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards) in the USA, the Physikalisch-Technische Bundesanstalt (PTB) in Germany, the National Research Council (NRC) in Canada, the National Physical Laboratory in the United Kingdom, International Time Bureau (French: Bureau International de l'Heure, abbreviated BIH), at the Paris Observatory, the National Radio Company, Bomac, Varian, Hewlett–Packard and Frequency & Time Systems. During the 1950s, the National Radio Company sold more than 50 units of the first atomic clock, the Atomichron. In 1964, engineers at Hewlett-Packard released the 5060 rack-mounted model of caesium clocks.
Definition of the second
Definition of the second
In 1968, the SI defined the duration of the second to be vibrations of the unperturbed ground-state hyperfine transition frequency of the caesium-133 atom. Prior to that it was defined by there being seconds in the tropical year 1900. In 1997, the International Committee for Weights and Measures (CIPM) added that the preceding definition refers to a caesium atom at rest at a temperature of absolute zero. Following the 2019 revision of the SI, the definition of every base unit except the mole and almost every derived unit relies on the definition of the second. Timekeeping researchers seek an even more stable atomic reference for the second, with a plan to find a more precise definition of the second as atomic clocks improve based on optical clocks or the Rydberg constant around 2030.
Metrology advancements and optical clocks
Metrology advancements and optical clocks
• Illustration — An ytterbium lattice clock that uses photons to measure time precisely Technological developments such as lasers and optical frequency combs in the 1990s led to increasing accuracy of atomic clocks. Lasers enable the possibility of optical-range control over atomic states transitions, which has a much higher frequency than that of microwaves; while optical frequency comb measures highly accurately such high frequency oscillation in light. The first advance beyond the precision of caesium clocks occurred at NIST in 2010 with the demonstration of a "quantum logic" optical clock that used aluminum ions to achieve a precision of. Optical clocks are a very active area of research in the field of metrology as scientists work to develop clocks based on elements ytterbium, mercury, aluminum, and strontium. Scientists at JILA demonstrated a strontium clock with a frequency precision of in 2015. Scientists at NIST developed a quantum logic clock that measured a single aluminum ion in 2019 with a frequency uncertainty of. At JILA in September 2021, scientists demonstrated an optical strontium clock with a differential frequency precision of between atomic ensembles separated by. The second is expected to be redefined when the field of optical clocks matures, sometime around the year 2030 or 2034. In order for this to occur, optical clocks must be consistently capable of measuring frequency with accuracy at or better than. In addition, methods for reliably comparing different optical clocks around the world in national metrology labs must be demonstrated, and the comparison must show relative clock frequency accuracies at or better than.
Chip-scale atomic clocks
Chip-scale atomic clocks
• Illustration — The heart of NIST's next-generation miniature atomic clock ticking at high "optical" frequencies is this vapor cell on a chip, shown next to a coffee bean for scale. Reducing the size and power consumption of optical clocks is necessary to enable their use in geodesy and GPS navigation. In August 2004, NIST scientists demonstrated a chip-scale atomic clock that was 100 times smaller than an ordinary atomic clock and had a much smaller power consumption of. The atomic clock was about the size of a grain of rice with a frequency of about 9 GHz. This technology became available commercially in 2011.
Clock mechanism
Clock mechanism
An atomic clock is based on a system of atoms which may be in one of two possible energy states. A group of atoms is prepared in a lower energy state, and then subjected to microwave radiation. If the radiation is of the correct frequency, a number of atoms will transition to the higher energy state. The closer the frequency is to the inherent oscillation frequency of the atoms, the more atoms will switch states. Such correlation allows very accurate tuning of the frequency of the microwave radiation. Once the microwave radiation is adjusted to a known frequency where the maximum number of atoms switch states, the atom and thus, its associated transition frequency, can be used as a timekeeping oscillator to measure elapsed time. All timekeeping devices use oscillatory phenomena to accurately measure time, whether it is the rotation of the Earth for a sundial, the swinging of a pendulum in a grandfather clock, the vibrations of springs and gears in a watch, or voltage changes in a quartz clock's crystal oscillator. However all of these are easily affected by temperature changes and are not very accurate. The most accurate clocks use atomic vibrations to keep track of time. Clock transition states in atoms are insensitive to temperature and other environmental factors and the oscillation frequency is much higher than any of the other clocks (in microwave frequency regime and higher). One of the most important factors in a clock's performance is the atomic line quality factor, which is defined as the ratio of the absolute frequency \nu_0 of the resonance to the linewidth of the resonance itself \Delta \nu. Atomic resonance has a much higher than mechanical devices. Atomic clocks can also be isolated from environmental effects to a much higher degree. Atomic clocks have the benefit that atoms are universal, which means that the oscillation frequency is also universal. This is different from quartz and mechanical time measurement devices that do not have a universal frequency. A clock's quality can be specified by two parameters: accuracy and stability. Accuracy is a measurement of the degree to which the clock's ticking rate can be counted on to match some absolute standard such as the inherent hyperfine frequency of an isolated atom or ion. Stability describes how the clock performs when averaged over time to reduce the impact of noise and other short-term fluctuations (see precision). The instability of an atomic clock is specified by its Allan deviation \sigma_y(\tau). The limiting instability due to atom or ion counting statistics is given by: \sigma_{y,\, {\rm atoms}}(\tau) \approx \frac{\Delta \nu}{\nu_0 \sqrt{N}} \sqrt{\frac{T_\text{c}}{\tau}}, where \Delta \nu is the spectroscopic linewidth of the clock system, N is the number of atoms or ions used in a single measurement, T_\text{c} is the time required for one cycle, and \tau is the averaging period. This means instability is smaller when the linewidth \Delta \nu is smaller and when \sqrt{N} (the signal to noise ratio) is larger. The stability improves as the time \tau over which the measurements are averaged increases from seconds to hours to days. The stability is most heavily affected by the oscillator frequency \nu_0. This is why optical clocks such as strontium clocks (429 terahertz) are much more stable than caesium clocks (9.19 GHz). Modern clocks such as atomic fountains or optical lattices that use sequential interrogation are found to generate a type of noise that mimics and adds to the instability inherent in atom or ion counting. This effect is called the Dick effect and is typically the primary stability limitation for the newer atomic clocks. It is an aliasing effect; high frequency noise components in the local oscillator ("LO") are heterodyned to near zero frequency by harmonics of the repeating variation in feedback sensitivity to the LO frequency. The effect places new and stringent requirements on the LO, which must now have low phase noise in addition to high stability, thereby increasing the cost and complexity of the system. For the case of an LO with flicker frequency noise where \sigma_y^{\rm LO}(\tau) is independent of \tau, the interrogation time is T_i, and where the duty factor d=T_i/T_c has typical values 0.4, the Allan deviation can be approximated as • \sigma_{y,\,{\rm Dick}}(\tau) \approx \frac{\sigma_y^{\rm LO}}{\sqrt{2\ln(2)}} \cdot \left|\frac{\sin(\pi d)}{\pi d}\right| \cdot \sqrt{\frac{T_c}{\tau}}. This expression shows the same dependence on T_c / {\tau} as does \sigma_{y,\, {\rm atoms}}(\tau), and, for many of the newer clocks, is significantly larger. Analysis of the effect and its consequence as applied to optical standards has been treated in a major review (Ludlow, et al., 2015) that lamented on "the pernicious influence of the Dick effect", and in several other papers.
Tuning and optimization
Tuning and optimization
The core of atomic clocks contain a microwave cavity containing a gas. In a hydrogen maser clock, the gas emits microwaves (masering) on a hyperfine transition. As the field in the cavity oscillates, the cavity is tuned for maximum microwave amplitude. The adjustment tries to correct for unwanted side-effects, such as frequencies from other electron transitions, temperature changes, and the spreading in frequencies caused by the vibration of molecules, including Doppler broadening. Many of the newer clocks, including microwave clocks such as trapped-ion or fountain clocks, and optical clocks such as lattice clocks, use a sequential interrogation protocol rather than the frequency-modulation interrogation. An advantage of sequential interrogation is that it can accommodate much higher Qs, with ringing times of seconds rather than milliseconds. These clocks also typically have a dead time, during which the atom or ion collections are analyzed, renewed and driven into a proper quantum state, after which they are interrogated with a signal from a local oscillator (LO) for a time of perhaps a second or so. Analysis of the final state of the atoms is then used to generate a correction signal to keep the LO frequency locked to that of the atoms or ions.
Accuracy
Accuracy
• Illustration — The historical accuracy of atomic clocks from NIST The accuracy of atomic clocks has improved continuously since the first prototype in the 1950s. The first generation of atomic clocks were based on measuring caesium, rubidium, and hydrogen atoms. In a time period from 1959 to 1998, NIST developed a series of seven caesium-133 microwave clocks, the NBS-1 to NBS-6, and the NIST-7 after the National Bureau of Standards changed to its current name. The first clock had an accuracy of, increasing to, or one per quadrillion, for the last clock. The clocks were the first to use a caesium fountain, which was introduced by Jerrod Zacharias, and laser cooling of atoms, which was demonstrated by Dave Wineland and his colleagues in 1978. The next step in atomic clock advances involves going from accuracies of to accuracies of and even. The goal is to redefine the second when clocks become so accurate that they will not lose or gain more than a second in the age of the universe. To do so, scientists must demonstrate the accuracy of clocks that use strontium and ytterbium and optical lattice technology. Such clocks are also called optical clocks where the energy level transitions used are in the optical regime (giving rise to even higher oscillation frequency), which thus, have much higher accuracy as compared to traditional atomic clocks. The goal of an atomic clock with accuracy was first reached at the United Kingdom's National Physical Laboratory's NPL-CsF2 caesium fountain clock and the United States' NIST-F2. The increase in precision from NIST-F1 to NIST-F2 is due to liquid nitrogen cooling of the microwave interaction region; the largest source of uncertainty in NIST-F1 is the effect of black-body radiation from the warm chamber walls. The performance of primary and secondary frequency standards contributing to International Atomic Time (TAI) is evaluated. The evaluation reports of individual (mainly primary) clocks are published online by the International Bureau of Weights and Measures (BIPM).
Time standards
Time standards
A number of national metrology laboratories maintain atomic clocks: including Paris Observatory, the Physikalisch-Technische Bundesanstalt (PTB) in Germany, the National Institute of Standards and Technology (NIST) in Colorado and Maryland, USA, JILA in the University of Colorado Boulder, the National Physical Laboratory (NPL) in the United Kingdom, and the All-Russian Scientific Research Institute for Physical-Engineering and Radiotechnical Metrology (VNIIFTRI). They do this by designing and building frequency standards that produce electric oscillations at a frequency whose relationship to the transition frequency of caesium 133 is known, in order to achieve a very low uncertainty. These primary frequency standards estimate and correct various frequency shifts, including relativistic Doppler shifts linked to atomic motion, the thermal radiation of the environment (blackbody shift) and several other factors. The best primary standards currently produce the SI second with an accuracy approaching an uncertainty of one part in. At this level of accuracy, the differences in the gravitational field in the device cannot be ignored. The standard is then considered in the framework of general relativity to provide a proper time at a specific point. Atomic time standards such as International Atomic Time (TAI) and Coordinated Universal Time (UTC) are disseminated to the public through satellite navigation systems, radio time signals, and network-based time services. In addition to official time authority websites, publicly accessible reference tools exist that allow users to compare the time reported by local computer systems with UTC obtained from national metrology institute time servers, such as those operated by the National Institute of Standards and Technology (NIST). These tools can be used to observe clock deviation and synchronization discrepancies in end-user devices. The International Bureau of Weights and Measures (BIPM) provides a list of frequencies that serve as secondary representations of the second. This list contains the frequency values and respective standard uncertainties for the rubidium microwave transition and other optical transitions, including neutral atoms and single trapped ions. These secondary frequency standards can be as accurate as one part in; however, the uncertainties in the list are one part in –. This is because the uncertainty in the central caesium standard against which the secondary standards are calibrated is one part in –. Primary frequency standards can be used to calibrate the frequency of other clocks used in national laboratories. These are usually commercial caesium clocks having very good long-term frequency stability, maintaining a frequency with a stability better than 1 part in over a few months. The uncertainty of the primary standard frequencies is around one part in. Hydrogen masers, which rely on the 1.4 GHz hyperfine transition in atomic hydrogen, are also used in time metrology laboratories. Masers outperform any commercial caesium clock in terms of short-term frequency stability. In the past, these instruments have been used in all applications that require a steady reference across time periods of less than one day (frequency stability of about 1 part in ten for averaging times of a few hours). Because some active hydrogen masers have a modest but predictable frequency drift with time, they have become an important part of the BIPM's ensemble of commercial clocks that implement International Atomic Time.
Synchronization with satellites
Synchronization with satellites
The time readings of clocks operated in metrology labs operating with the BIPM need to be known very accurately. Some operations require synchronization of atomic clocks separated by great distances over thousands of kilometers. Global Navigational Satellite Systems (GNSS) provide a satisfactory solution to the problem of time transfer. Atomic clocks are used to broadcast time signals in the United States Global Positioning System (GPS), the Russian Federation's Global Navigation Satellite System (GLONASS), the European Union's Galileo system and China's BeiDou system. The signal received from one satellite in a metrology laboratory equipped with a receiver with an accurately known position allows the time difference between the local time scale and the GNSS system time to be determined with an uncertainty of a few nanoseconds when averaged over 15 minutes. Receivers allow the simultaneous reception of signals from several satellites, and make use of signals transmitted on two frequencies. As more satellites are launched and start operations, time measurements will become more accurate. These methods of time comparison must make corrections for the effects of special relativity and general relativity of a few nanoseconds. In June 2015, the National Physical Laboratory (NPL) in Teddington, UK; the French department of Time-Space Reference Systems at the Paris Observatory (LNE-SYRTE); the German German National Metrology Institute (PTB) in Braunschweig; and Italy's Istituto Nazionale di Ricerca Metrologica (INRiM) in Turin labs started tests to improve the accuracy of satellite comparisons by a factor of 10, but still be limited to one part in. These four European labs are developing and host a variety of experimental optical clocks that harness different elements in different experimental set-ups and want to compare their optical clocks against each other and check whether they agree.
International timekeeping
International timekeeping
• Illustration — Data points representing atomic clocks around the world that define International Atomic Time (TAI) National laboratories usually operate a range of clocks. These are operated independently of one another and their measurements are sometimes combined to generate a scale that is more stable and more accurate than that of any individual contributing clock. This scale allows for time comparisons between different clocks in the laboratory. These atomic time scales are generally referred to as TA(k) for laboratory k. Coordinated Universal Time (UTC) is the result of comparing clocks in national laboratories around the world to International Atomic Time (TAI), then adding leap seconds as necessary. TAI is a weighted average of around 450 clocks in some 80 time institutions. The relative stability of TAI is around one part in. Before TAI is published, the frequency of the result is compared with the SI second at various primary and secondary frequency standards. This requires relativistic corrections to be applied to the location of the primary standard which depend on the distance between the equal gravity potential and the rotating geoid of Earth. The values of the rotating geoid and the TAI change slightly each month and are available in the BIPM Circular T publication. The TAI time-scale is deferred by a few weeks as the average of atomic clocks around the world is calculated. TAI is not distributed in everyday timekeeping. Instead, an integer number of leap seconds are added or subtracted to correct for the Earth's rotation, producing UTC. The number of leap seconds is changed so that mean solar noon at the prime meridian (Greenwich) does not deviate from UTC noon by more than 0.9 seconds. National metrology institutions maintain an approximation of UTC referred to as UTC(k) for laboratory k. UTC(k) is distributed by the BIPM's Consultative Committee for Time and Frequency. The offset UTC-UTC(k) is calculated every 5 days, the results are published monthly. Atomic clocks record UTC(k) to no more than 100 nanoseconds. In some countries, UTC(k) is the legal time that is distributed by radio, television, telephone, Internet, fiber-optic cables, time signal transmitters, and speaking clocks. In addition, GNSS provides time information accurate to a few tens of nanoseconds or better.
Fiber optics
Fiber optics
In a next phase, these labs strive to transmit comparison signals in the visible spectrum through fibre-optic cables. This will allow their experimental optical clocks to be compared with an accuracy similar to the expected accuracies of the optical clocks themselves. Some of these labs have already established fibre-optic links, and tests have begun on sections between Paris and Teddington, and Paris and Braunschweig. Fibre-optic links between experimental optical clocks also exist between the American NIST lab and its partner lab JILA, both in Boulder, Colorado but these span much shorter distances than the European network and are between just two labs. According to Fritz Riehle, a physicist at PTB, "Europe is in a unique position as it has a high density of the best clocks in the world". In August 2016 the French LNE-SYRTE in Paris and the German PTB in Braunschweig reported the comparison and agreement of two fully independent experimental strontium lattice optical clocks in Paris and Braunschweig at an uncertainty of via a newly established phase-coherent frequency link connecting Paris and Braunschweig, using 1415 km of telecom fibre-optic cable. The fractional uncertainty of the whole link was assessed to be, making comparisons of even more accurate clocks possible. In 2021, NIST compared transmission of signals from a series of experimental atomic clocks located about 1.5 km apart at the NIST lab, its partner lab JILA, and the University of Colorado all in Boulder, Colorado over air and fiber optic cable to a precision of.
Caesium
Caesium
The SI second is defined as a certain number of unperturbed ground-state hyperfine transitions of the caesium-133 atom. Caesium standards are therefore regarded as primary time and frequency standards. Caesium clocks include the NIST-F1 clock, developed in 1999, and the NIST-F2 clock, developed in 2013. Caesium has several properties that make it a good choice for an atomic clock. Whereas a hydrogen atom moves at 1,600 m/s at room temperature and a nitrogen atom moves at 510 m/s, a caesium atom moves at a much slower speed of 130 m/s due to its greater mass. The hyperfine frequency of caesium (~9.19 GHz) is also higher than other elements such as rubidium (~6.8 GHz) and hydrogen (~1.4 GHz). The high frequency of caesium allows for more accurate measurements. Caesium reference tubes suitable for national standards currently last about seven years and cost about US$35,000. Primary frequency and time standards like the United States Time Standard atomic clocks, NIST-F1 and NIST-F2, use far higher power.
Block diagram
Block diagram
In a caesium beam frequency reference, timing signals are derived from a high stability voltage-controlled quartz crystal oscillator (VCXO) that is tunable over a narrow range. The output frequency of the VCXO (typically 5 MHz) is multiplied by a frequency synthesizer to obtain microwaves at the frequency of the caesium atomic hyperfine transition (about). The output of the frequency synthesizer is amplified and applied to a chamber containing caesium gas which absorbs the microwaves. The output current of the caesium chamber increases as absorption increases. The remainder of the circuitry simply adjusts the running frequency of the VCXO to maximize the output current of the caesium chamber which keeps the oscillator tuned to the resonance frequency of the hyperfine transition.
Rubidium
Rubidium
• Illustration — A team of United States Air Force airmen carrying a rubidium clock The BIPM defines the unperturbed ground-state hyperfine transition frequency of the rubidium-87 atom; in terms of the caesium standard frequency. Atomic clocks based on rubidium standards are therefore regarded as secondary representations of the second. The advantages of rubidium atomic clocks are their low cost, small size (commercial standards are as small as) and short-term stability. They are used in many commercial, portable and aerospace applications. Modern rubidium standard tubes last more than ten years, and can cost as little as US$50. Some commercial applications use a rubidium standard periodically corrected by a global positioning system receiver (see GPS-disciplined oscillator). This achieves excellent short-term accuracy, with long-term accuracy equal to (and traceable to) the US national time standards.
Hydrogen
Hydrogen
• Illustration — A hydrogen maser The BIPM defines the unperturbed optical transition frequency of the hydrogen-1 neutral atom; in terms of the caesium standard frequency. Atomic clocks based on hydrogen standards are therefore regarded as secondary representations of the second. Hydrogen masers have superior short-term stability compared to other standards, but lower long-term accuracy. The long-term stability of hydrogen maser standards decreases because of changes in the cavity's properties over time. The relative error of hydrogen masers is 5 × 10 −16 for periods of 1000 seconds. This makes hydrogen masers good for radio astronomy, in particular for very long baseline interferometry. Hydrogen masers are used for flywheel oscillators in laser-cooled atomic frequency standards and broadcasting time signals from national standards laboratories, although they need to be corrected as they drift from the correct frequency over time. The hydrogen maser is also useful for experimental tests of the effects of special relativity and general relativity such as gravitational red shift.
Optical atomic clocks
Optical atomic clocks
Optical clocks operate similarly to microwave clocks, but at much higher frequencies, around rather than the range of microwave clocks. The advantage of optical clocks can be explained by the statement that the instability \sigma\propto \frac{\Delta f}{f} \frac{1}{S/N}, where \sigma is the instability, f is the frequency, and S/N is the signal-to-noise ratio. This leads to the equation \sigma(\tau)=\frac{1}{2 \pi f \sqrt{N T_{int} \tau}}. Optical clocks are based on forbidden optical transitions in ions or atoms, with a natural linewidth \Delta f of typically 1 Hz, so the Q-factor is about. Compared to microwave clocks, the times higher frequency gives better stability, which means that they can facilitate evaluation of lower uncertainties. The faster "ticking" also gives better time resolution for short intervals. Optical clocks were enabled by the development of the frequency comb, which allowed cycle-exact counting of these extremely high optical frequencies. Optical clocks use either a single ion, multiple ions in a Coulomb crystal (see Coulomb crystal clock) or an optical lattice with – atoms.
Nuclear concept
Nuclear concept
A further variation on the optical atomic clock being developed the use of a nuclear energy transition (between different nuclear isomers) rather than the atomic electron transitions which current atomic clocks measure. Most nuclear transitions operate at far too high a frequency to be measured, but the exceptionally low excitation energy of Thorium produces "gamma rays" in the ultraviolet frequency range. In 2003, Ekkehard Peik and Christian Tamm noted this makes a clock possible with current optical frequency-measurement techniques. In 2012, it was shown that a nuclear clock based on a single ion could provide a total fractional frequency inaccuracy of, which was better than existing 2019 optical atomic clock technology. Although neutral atoms decay in microseconds by internal conversion, this pathway is energetically prohibited in ions, as the second and higher ionization energy is greater than the nuclear excitation energy, giving ions a long half-life on the order of. It is the large ratio between transition frequency and isomer lifetime which gives the clock a high quality factor. The extremely high quality factor also makes the transition frequency very difficult to find, and the 2010s were spent searching for it. A sufficiently precise measurement was finally achieved in 2024 as. The first experimental optical nuclear clocks were announced in June 2026. They are not yet competitive with other atomic clocks, but development is expected to be rapid. A nuclear energy transition offers the following potential advantages: • Higher frequency. All other things being equal, a higher-frequency transition offers greater stability for simple statistical reasons (fluctuations are averaged over more cycles). • Insensitivity to environmental effects. Due to its small size and the shielding effect of the surrounding electrons, an atomic nucleus is much less sensitive to ambient electromagnetic fields than is an electron in an orbital. • Greater number of atoms. Because of the aforementioned insensitivity to ambient fields, it is not necessary to have the clock atoms well-separated in a dilute gas. Current measurements take advantage of the Mössbauer effect and place the thorium ions in a solid, which allows billions of atoms to be interrogated.
Potential for redefining the second
Potential for redefining the second
In 2022, the best realisation of the second is done with caesium fountain primary standard clocks such as IT-CsF2, NIST-F2, NPL-CsF2, PTB-CSF2, SU–CsFO2 or SYRTE-FO2. These clocks work by laser-cooling a cloud of caesium atoms to a microkelvin in a magneto-optic trap. These cold atoms are then launched vertically by laser light. The atoms then undergo Ramsey excitation in a microwave cavity. The fraction of excited atoms are then detected by laser beams. These clocks have systematic uncertainty, which is equivalent to per day. A system of several fountains worldwide contributes to International Atomic Time. These caesium clocks also underpin optical frequency measurements. The development of optical alomic clocks more stable than the best caesium clocks has led to proposals for redefining the second more accurately. However, there are several optical clock systems in active development, and it is not clear which is the best to serve as a long-term replacement for the caesium standard.
Rydberg constant
Rydberg constant
An alternative would be to define the second by fixing the Rydberg constant to a certain value: R_{\infty}=\frac{m_e e^4}{8 \varepsilon_0^2 h ^3 c}=\frac{m_e c \alpha^2}{2h}. The Rydberg constant describes the energy levels in a hydrogen atom with the nonrelativistic approximation E_n \approx -\frac{R_{\infty} c h}{n^2}. The only viable way to fix the Rydberg constant involves trapping and cooling hydrogen atoms. Unfortunately, this is difficult because they are very light and move very fast, causing Doppler shifts. The radiation needed to cool the hydrogen —— is also difficult to work with. Another hurdle involves improving the uncertainty in quantum electrodynamics/QED calculations. In the Report of the 25th meeting of the Consultative Committee for Units (2021), 3 options were considered for the redefinition of the second sometime around 2026, 2030, or 2034. The first redefinition approach considered was a definition based on a single atomic reference transition. The second redefinition approach considered was a definition based on a collection of frequencies. The third redefinition approach considered was a definition based on fixing the numerical value of a fundamental constant, such as making the Rydberg constant the basis for the definition. The committee concluded there was no feasible way to redefine the second with the third option, since no physical constant is known to enough digits currently to enable realizing the second with a constant.
Requirements
Requirements
A redefinition must include improved optical clock reliability. TAI must be contributed to by optical clocks before the BIPM affirms a redefinition. A consistent method of communicating the resultant signals, such as fibre optics, must be developed before the second is redefined.
Secondary representations of the second
Secondary representations of the second
Representations of the second other than the SI cesium standard are motivated by the increasing accuracy of other atomic clocks. In particular the high frequencies and small linewidths of optical clocks promise significantly improved signal-to-noise ratio and instability. Further secondary representations would aid in the preparation of a future redefinition of the second. A list of frequencies recommended for secondary representations of the second is maintained by the International Bureau of Weights and Measures (BIPM) since 2006 and is available online. The list contains the frequency values and the respective standard uncertainties for the rubidium microwave transition and for several optical transitions. These secondary frequency standards are accurate at the level of; however, the uncertainties provided in the list are in the range – since they are limited by the linking to the caesium primary standard that currently (2018) defines the second. • Type — Working frequency (Hz) — Relative Allan deviation (typical clocks) — Reference • 133 Cs — by definition • 87 Rb • 1 H • Optical clock (87 Sr) • Optical clock (27 Al +) • Optical clock (171 Yb +, 642 THz) • Optical clock (171 Yb +, 688 THz) Twenty-first century experimental atomic clocks that provide non-caesium-based secondary representations of the second are becoming so precise that they are likely to be used as extremely sensitive detectors for other things besides measuring frequency and time. For example, the frequency of atomic clocks is altered slightly by gravity, magnetic fields, electrical fields, force, motion, temperature and other phenomena. The experimental clocks tend to continue to improve, and leadership in performance has shifted back and forth between various types of experimental clocks.
Applications
Applications
• Illustration — Atomic clocks and their usage in GPS, by Bill Hammack The development of atomic clocks has led to many scientific and technological advances such as precise global and regional navigation satellite systems, and applications in the Internet, which depend critically on frequency and time standards. Atomic clocks are installed at sites of time signal radio transmitters. They are used at some long-wave and medium-wave broadcasting stations to deliver a very precise carrier frequency. Atomic clocks are used in many scientific disciplines, such as for long-baseline interferometry in radio astronomy.
Global navigation satellite systems
Experimental space clock
Experimental space clock
In April 2015, NASA announced that it planned to deploy a Deep Space Atomic Clock (DSAC), a miniaturized, ultra-precise mercury-ion atomic clock, into outer space. NASA said that the DSAC would be much more stable than other navigational clocks. The clock was successfully launched on 25 June 2019, activated on 23 August 2019 and deactivated two years later on 18 September 2021.
Military usage
Military usage
In 2022, DARPA announced a drive to upgrade to the U.S. military timekeeping systems for greater precision over time when sensors do not have access to GPS satellites, with a plan to reach precision of 1 part in. The Robust Optical Clock Network will balance usability and accuracy as it is developed over 4 years.
Time signal radio transmitters
Time signal radio transmitters
A radio clock is a clock that automatically synchronizes itself by means of radio time signals received by a radio receiver. Some manufacturers may label radio clocks as atomic clocks, because the radio signals they receive originate from atomic clocks. Normal low-cost consumer-grade receivers that rely on the amplitude-modulated time signals have a practical accuracy uncertainty of ± 0.1 second. This is sufficient for many consumer applications. Instrument grade time receivers provide higher accuracy. Radio clocks incur a propagation delay of approximately 1 ms for every 300 kilometres (186 mi) of distance from the radio transmitter. Many governments operate transmitters for timekeeping purposes.
General relativity
General relativity
General relativity predicts that clocks tick slower deeper in a gravitational field, and this gravitational redshift effect has been well documented. Atomic clocks are effective at testing general relativity on ever smaller scales. A project to observe twelve atomic clocks from 11 November 1999 to October 2014 resulted in a further demonstration that Einstein's theory of general relativity is accurate at small scales. In 2021 a team of scientists at JILA measured the difference in the passage of time due to gravitational redshift between two layers of atoms separated by one millimeter using a strontium optical clock cooled to 100 nanokelvins with a precision of seconds. Given its quantum nature and the fact that time is a relativistic quantity, atomic clocks can be used to see how time is influenced by general relativity and quantum mechanics at the same time.
Financial systems
Financial systems
Atomic clocks keep accurate records of transactions between buyers and sellers to the millisecond or better, particularly in high-frequency trading. Accurate timekeeping is needed to prevent illegal trading ahead of time, in addition to ensuring fairness to traders on the other side of the globe. In 2018, the then current system known as NTP is only accurate to a millisecond.
Transportable Optical Clocks
Transportable Optical Clocks
Many of the most accurate optical clocks are big and only available in large metrology labs. Thus they are not readily useful for space-limited factories or other industrial environments that could use an atomic clock for GPS accuracy. Researchers have designed a strontium optical lattice clock that can be moved around in an air-conditioned car trailer. They achieved a relative uncertainty of compared to a stationary one.
Manufacturers
Manufacturers
Manufacturers of atomic clocks in use for keeping track of UTC includes Microchip, T4Science, Anritsu, Microsemi and HP.

At a ceremony held on 14 November 2013 at the La Moneda Palace, Sebastián Piñera, the President of Chile, received the first atomic clock used by ESO in Chile from Tim de Zeeuw, ESO Director General. This gift, a timepiece that was originally installed at ESO’s La Silla Observatory in 1975, was in gratitude for fifty years of successful collaboration between ESO and the host country.
ESO
Primary material
Documents and archives
institutional register
- Bibliothèque nationale de France authority file 11980310n
Unverified · Bibliothèque nationale de France
- GND (German National Library) authority file 4259141-7
Unverified · GND (German National Library)
- Internet Archive holdings naming atomic clock
Unverified · Internet Archive
- Library of Congress authority file sh85009316
Unverified · Library of Congress
- Wikidata, structured authority record Q227467: atomic clock
Unverified · Wikimedia Foundation
reference work
- “Atomic clock”, English Wikipedia, consulted as further reading
Reputable secondary · Wikipedia
Notes from the source article
Cited by Wikipedia
Notes from the source article
These works are cited by the source article, in its own numbering. They are recorded as its citations, not as sources VALÉORINE has verified.
- 1.USNO Master Clock.
- 2.NIST Launches a New U.S. Time Standard: NIST-F2 Atomic Clock. NIST. 3 April 2014.
- 3.First Accuracy Evaluation of NIST-F2. Metrologia. 51. 3. 174–182. May 2014. 10.1088/0026-1394/51/3/174.
- 4.NIST Ion Clock Sets New Record for Most Accurate Clock in the World.
- 5.NIST's ion clock claims record for 'most accurate in the world'.
- 6.Roadmap to the redefinition of the second.
- 7.Unprecedented optical clock network lays groundwork for redefining the second.
- 8.Optical Clocks: The Future of Time.
- 9.Ramsey, Norman F. History of early atomic clocks. Metrologia. 42. 3. S1–S3. June 2006. 0026-1394.
- 10.Achard, F. Landmark Writings in Western Mathematics 1640–1940. Elsevier. 564–587. 2005. 978-0-444-50871-3.
- 11.Milestones:First Atomic Clock, 1948. ETHW. 14 June 2022.
- 12.Rabi, I. I. Space Quantization in a Gyrating Magnetic Field. Physical Review. 51. 8. 652–654. 15 April 1937. 0031-899X.
- 13.Rabi, I. I. A New Method of Measuring Nuclear Magnetic Moment. Physical Review. 53. 4. 318. 15 February 1938. 0031-899X.
- 14.Lombardi, M. A. NIST Primary Frequency Standards and the Realization of the SI Second. Journal of Measurement Science. 2. 4. 74–89. 2007.
- 15.Sullivan, D. B. Time and frequency measurement at NIST: The first 100 years. NIST. 4–17. 2001.
- 16.Essen, L. An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator. Nature. 176. 4476. 280–282. 1955. 10.1038/176280a0.
- 17.60 years of the Atomic Clock. National Physical Laboratory.
- 18.Essen, L. An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator. Nature. 176. 4476. 280. 1955. 10.1038/176280a0.
- 19.President Piñera Receives ESO's First Atomic Clock. ESO Announcement. 15 November 2013.
- 20.Ramsey, N. F. History of Atomic Clocks. Journal of Research of the National Bureau of Standards. 88. 5. 301–320. September 1983. 0160-1741.
- 21.WORLD SCIENTIFIC. Spectroscopy With Coherent Radiation. 21. 115–127. June 1998. 978-981-02-3250-4.
- 22.Hellwig, Helmut. Time, frequency and physical measurement. Physics Today. 31. 12. 23–30. December 1978. 0031-9228.
- 23.Forman, Paul. Atomichron: The Atomic Clock from Concept to Commercial Product. 1998.
- 24.McCarthy, D. D. TIME—From Earth Rotation to Atomic Physics. Wiley-VCH. 191–195. 2009. 978-3-527-40780-4.
- 25.SIbrochure8th
- 26.Fox, Alex. New Atomic Clocks May Someday Redefine the Length of a Second. Smithsonian Magazine.
- 27.Lodewyck, Jérôme. On a definition of the SI second with a set of optical clock transitions. Metrologia. 56. 5. 16 September 2019. 0026-1394.
- 28.Ye, J. Optical frequency combs: From frequency metrology to optical phase control. IEEE Journal of Selected Topics in Quantum Electronics. 9. 4. 1041–1058. 2003. 10.1109/JSTQE.2003.819109.
- 29.NIST. Optical Frequency Combs. 31 December 2009.
- 30.swenson. NIST's Second 'Quantum Logic Clock' Based on Aluminum Ion is Now World's Most Precise Clock. NIST. 4 February 2010.
- 31.Nicholson, T. L. Systematic evaluation of an atomic clock at total uncertainty. Nature Communications. 6. 1. 21 April 2015. 2041-1723.
- 32.sarah.henderson@nist.gov. NIST's Quantum Logic Clock Returns to Top Performance. NIST. 15 July 2019.
- 33.Brewer, S. M. Al+27 Quantum-Logic Clock with a Systematic Uncertainty below. Physical Review Letters. 123. 3. 15 July 2019. 0031-9007.
- 34.Bothwell, Tobias. Resolving the gravitational redshift across a millimetre-scale atomic sample. Nature. 602. 7897. 420–424. 16 February 2022. 0028-0836.
- 35.An atomic clock measured how general relativity warps time across a millimeter. Science News. 18 October 2021.
- 36.Dimarcq, Noel. Roadmap towards the redefinition of the second. Metrologia. 61. 1. 012001. 2024. 10.1088/1681-7575/ad17d2.
- 37.SA.45s CSAC Chip Scale Atomic Clock (archived version of the original pdf). 2011.
- 38.NIST Available on-line at: NIST.gov. Webarchive. Chip-Scale Atomic Devices at NIST. 7 January 2021.
- 39.How Do Atomic Clocks Work?. www.timeanddate.com.
- 40.Poli, N. Optical atomic clocks. La Rivista del Nuovo Cimento. 36. 12. 555. 2014. 10.1393/ncr/i2013-10095-x.
- 41.Allan, David W. Statistics of Atomic Frequency Standards, pp. 221–230. Proceedings of the IEEE, Vol. 54, No 2, February 1966.
- 42.Dick, G. J. Local oscillator induced instabilities in trapped ion frequency standards. 1987.
- 43.J. A. Barnes, A. R. Chi, L. S. Cutler, D. J. Healey, D. B. Leeson, T. E. McGunigal, J. A. Mullen, W. L. Smith, R. Sydnor, R. F. C. Vessot, G. M. R. Winkler: Characterization of Frequency Stability, NBS Technical Note 394, 1970.
- 44.Frequency stability degradation of an oscillator slaved to a periodically interrogated atomic resonator. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 45. 4. 887–894. 1998. 10.1109/58.710548.
- 45.Ludlow, A. D. Optical atomic clocks. Reviews of Modern Physics. 87. 2. 637–701. June 26, 2015. 10.1103/RevModPhys.87.637.
- 46.The Dick effect for an optical frequency standard. Journal of Optics B: Quantum and Semiclassical Optics. 5. 2. S150–S154. April 2, 2003. 10.1088/1464-4266/5/2/373.
- 47.Westergaard, P. G. Minimizing the Dick effect in an optical lattice clock. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 57. 3. 623–628. March 2010. 10.1109/TUFFC.2010.1457.
- 48.NIST. NIST Primary Frequency Standards and the Realization of the SI Second. NCSL International Measure. 2. 77. December 2007.
- 49.University of Wisconsin-Madison. Ultraprecise atomic clock poised for new physics discoveries.
- 50.What Are Optical Clocks and Why Are They Important?. Revolutionalized. 20 July 2021.
- 51.Laboratory, National Physical. Accuracy of the NPL caesium fountain clock further improved. phys.org.
- 52.The atomic clock with the world's best long-term accuracy is revealed after evaluation. EurekAlert!.
- 53.2016 Gets Longer with Extra Second Added to New Year Countdown Sci-News.com. Breaking Science News Sci-News.com. 23 December 2016.
- 54.Mann, Adam. How the U.S. Built the World's Most Ridiculously Accurate Atomic Clock. Wired. 1059-1028.
- 55.robin.materese@nist.gov. Second: The Future. NIST. 9 April 2019.
- 56.nist.gov. NIST launches a new US time standard: NIST-F2 atomic clock. NIST. 3 April 2014.
- 57.Realizing and disseminating international reference time scales UTC, UTCr and TT(BIPM). BIPM.
- 58.Consultative Committee for Time and Frequency. Mise en pratique for the definition of the second in the SI. Bureau International Poids et Mesures. 20 May 2019.
- 59.National Institute of Standards and Technology. Official U.S. time.
- 60.UTC time comparison using NIST NTP sources. ttime.is.
- 61.Gibney, Elizabeth. Hyper-precise atomic clocks face off to redefine time – Next-generation timekeepers can only be tested against each other. Nature. 522. 7554. 16–17. 2 June 2015. 10.1038/522016a.
- 62.International Bureau of Weights and Measures. Explanatory Supplement of BIPM Circular T. 12 July 2021.
- 63.International Bureau of Weights and Measures. BIPM Annual Report on Time Activities. 15. 9. 2020. 978-92-822-2280-5.
- 64.Pottie, Paul-Eric. A clock network for geodesy and fundamental science. Nature Communications. 7. 19 August 2016. 10.1038/ncomms12443.
- 65.Optical fibre link opens a new era of time-frequency metrology, 19 August 2016.
- 66.Beloy, Kyle. Frequency ratio measurements at 18-digit accuracy using an optical clock network. Nature. 591. 7851. 564–569. 25 March 2021. 1476-4687.
- 67.sarah.henderson@nist.gov. NIST Team Compares 3 Top Atomic Clocks With Record Accuracy Over Both Fiber and Air. NIST. 24 March 2021.
- 68.swenson. NIST-F1 Cesium Fountain Clock. NIST. 29 December 1999.
- 69.mweiss. NIST-F1 Cesium Fountain Atomic Clock. NIST. 26 August 2009.
- 70.Temperature and Kinetic Energy – Answers. www.grc.nasa.gov.
- 71.NIST Launches a New U.S. Time Standard: NIST-F2 Atomic Clock. NIST. 3 April 2014.
- 72.University, Lancaster. Clock Experiment Shows a Fundamental Connection Between Energy Consumption and Accuracy. SciTechDaily. 11 May 2021.
- 73.Vleugels, Anouk. New experiment: Clocks consuming more energy are more accurate… 'cause thermodynamics. TNW Science. 23 May 2021.
- 74.A Cesium Beam Frequency Reference for Severe Environment.
- 75.National Physical Laboratory. OC18. National Physical laboratory. 2019.
- 76.Gill, Patrick. When should we change the definition of the second?. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. 369. 1953. 4109–4130. 28 October 2011. 10.1098/rsta.2011.0237.
- 77.Peik, E. Nuclear laser spectroscopy of the 3.5 eV transition in 229 Th. Europhysics Letters. 61. 2. 181–186. 15 January 2003. 10.1209/epl/i2003-00210-x.
- 78.Campbell, C. A single ion nuclear clock for metrology at the 19th decimal place. Phys. Rev. Lett. 108. 12. 2012. 10.1103/PhysRevLett.108.120802.
- 79.Seiferle, Benedict. Lifetime measurement of the 229 Th nuclear isomer. Physical Review Letters. 118. 4. 2017. 10.1103/PhysRevLett.118.042501.
- 80.von der Wense, Lars. Direct detection of the 229 Th nuclear clock transition. Nature. 533. 7601. 47–51. 5 May 2016. 10.1038/nature17669.
- 81.Thielking, J. Laser spectroscopic characterization of the nuclear-clock isomer 229m Th. Nature. 556. 7701. 321–325. 2018. 10.1038/s41586-018-0011-8.
- 82.Masuda, T. X-ray pumping of the 229 Th nuclear clock isomer. Nature. 573. 7773. 238–242. 12 September 2019. 10.1038/s41586-019-1542-3.
- 83.Seiferle, B. Energy of the 229 Th nuclear clock transition. Nature. 573. 7773. 243–246. 12 September 2019. 10.1038/s41586-019-1533-4.
- 84.Thirolf, Peter. Shedding Light on the Thorium-229 Nuclear Clock Isomer. Physics. 17. April 29, 2024. 10.1103/Physics.17.71.
- 85.Tiedau, J. Laser Excitation of the Th-229 Nucleus. Physical Review Letters. 132. 18. 29 April 2024. 10.1103/PhysRevLett.132.182501.
- 86.Elwell, R. Laser excitation of the 229 Th nuclear isomeric transition in a solid-state host. Physical Review Letters. 133. 1. 2 July 2024. 10.1103/PhysRevLett.133.013201.
- 87.Zhang, Chuankun. Frequency ratio of the 229m Th nuclear isomeric transition and the 87 Sr atomic clock. Nature. 633. 8028. 63–70. 4 September 2024. 10.1038/s41586-024-07839-6.
- 88.Jarman, Sam. Nuclear clocks tick for the first time. Phys.org. 12 June 2026.
- 89.Conover, Emily. Clocks made from an atomic nucleus just ticked on for the first time. ScienceNews. 11 June 2026.
- 90.Toscani De Col, Luca. A thorium-229 optical nuclear clock with feedback loop. 3 Jun 2026.
- 91.Huang, Beichen. A nuclear clock based on 229 Th. 7 Jun 2026.
- 92.Conover, Emily. A nuclear clock prototype hints at ultraprecise timekeeping. ScienceNews. 4 September 2024.
- 93.Peik, Ekkehard. Concepts and Prospects for a Thorium-229 Nuclear Clock. 25–27 September 2012.
- 94.Gill, Patrick. When should we change the definition of the second?. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. 369. 1953. 4109–4130. 28 October 2011. 10.1098/rsta.2011.0237.
- 95.Consultative Committee for Units (CCU) Report of the 25th meeting (21-23 September 2021) to the International Committee for Weights and Measures.
- 96.Riehle, Fritz. On Secondary Representations of the Second. Physikalisch-Technische Bundesanstalt, Division Optics. 11 August 2008.
- 97.BIPM. SI Brochure. 2014.
- 98.87 Rubidium BIPM document.
- 99.Essen, L. Hydrogen Maser Work at the National Physical Laboratory. Metrologia. 9. 3. 128–137. July 1973. 10.1088/0026-1394/9/3/004.
- 100.Dupays, Arnaud. Proton Zemach radius from measurements of the hyperfine splitting of hydrogen and muonic hydrogen. Physical Review A. 68. 5. August 2003. 10.1103/PhysRevA.68.052503.
- 101.87 Strontium BIPM document.
- 102.27 Aluminum ion BIPM document.
- 103.Brewer, S. 27 Al + Quantum-Logic Clock with a Systematic Uncertainty below 10 −18. Physical Review Letters. 123. 3. 15 July 2019. 10.1103/PhysRevLett.123.033201.
- 104.171 Ytterbium 171 ion (642 THz) BIPM document.
- 105.Huntemann, N. Single-Ion Atomic Clock with 3×10 −18 Systematic Uncertainty. Physical Review Letters. 116. 6. 8 February 2016. 10.1103/PhysRevLett.116.063001.
- 106.171 Ytterbium 171 ion (688 THz) BIPM document.
- 107.Leute, J. Frequency Comparison of 171 Yb + Ion Optical Clocks at PTB and NPL via GPS PPP. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 63. 7. 981–985. 3 February 2016. 10.1109/TUFFC.2016.2524988.
- 108.StackPath. www.laserfocusworld.com. September 2001.
- 109.Ahmed, Issam. What the world's most accurate clock can tell us about Earth and the cosmos. phys.org.
- 110.New type of atomic clock keeps time even more precisely. MIT News Massachusetts Institute of Technology. 16 December 2020.
- 111.Woodward, Aylin. The most precise atomic clock ever made is a cube of quantum gas. New Scientist. 5 October 2017.
- 112.Ren, Wei. Development of a space cold atom clock. National Science Review. 7. 12. 1828–1836. 18 December 2020. 2095-5138.
- 113.andrew.novick@nist.gov. Help with WWVB Radio Controlled Clocks. NIST. 11 February 2010.
- 114.McCarthy, D. D. TIME—From Earth Rotation to Atomic Physics. Wiley-VCH. 266. 2009. 978-3-527-40780-4.
- 115.Gps.gov. Global Positioning System.
- 116.Allan, David W. The Science of Timekeeping. Application Note. Hewlett Packard. 1289. 1997.
- 117.Dana, Peter H. The Role of GPS in Precise Time and Frequency Dissemination. GPSworld. July–August 1990.
- 118.Galleon. GPS time accurate to 100 nanoseconds.
- 119.UTC to GPS Time Correction. qps.nl.
- 120.NAVSTAR GPS User Equipment Introduction.
- 121.NOTICE ADVISORY TO NAVSTAR USERS (NANU). May 2017.
- 122.GPS Operations Center. Notice Advisory to Navstar Users (NANU) 2012034. 30 May 2012.
- 123.Time References in GNSS. navipedia.net.
- 124.GLONASS Interface Control Document, Navigation radiosignal In bands L1, L2 (ICD L1, L2 GLONASS), Russian Institute of Space Device Engineering, Edition 5.1, 2008.
- 125.European Space Agency. Galileo begins serving the globe.
- 126.European GNSS (Galileo) Open Service Signal-In-Space Operational Status Definition, Issue 1.0, September 2015.
- 127.1 The Definition and Implementation of Galileo System Time (GST). ICG-4 WG-D on GNSS time scales. Jérôme Delporte. CNES – French Space Agency.
- 128.European Space Agency. Galileo's clocks.
- 129.European Commission. Galileo's contribution to the MEOSAR system.
- 130.European GNSS Agency. Galileo Goes Live. 15 December 2016.
- 131.European GNSS Service Centre. Galileo Initial Services – Open Service – Quarterly Performance Report Oct–Nov–Dec 2017. 28 March 2018.
- 132.Galileo Open Service and Search and Rescue – Quarterly Performance Reports, containing measured performance statistics.
- 133.Passive Hydrogen Maser (PHM). Safran - Navigation & Timing.
- 134.Rb Atomic Frequency Standard (RAFS). safran-navigation-timing.com.
- 135.GNSS Timescale Description.
- 136.ESA Adds System Time Offset to Galileo Navigation Message. insidegnss.com.
- 137.Belcher, David. Trying to Get Somewhere? An Atomic Clock May Be Helping. The New York Times. 1 November 2021. 0362-4331.
- 138.China Satellite Navigation Office, Version 2.0, December 2013
- 139.Definition and Realization of the System Time of COMPASS/BeiDou Navigation Satellite System, Chunhao Han, Beijing Global Information Center,(BGIC), Beijing, China.
- 140.BBC. China GPS rival Beidou starts offering navigation data. 27 December 2011.
- 141.BBC. China's Beidou GPS-substitute opens to public in Asia. 27 December 2012.
- 142.Varma, K. J. M. China's BeiDou navigation satellite, rival to US GPS, starts global services. livemint.com. 27 December 2018.
- 143.China puts final satellite for Beidou network into orbit – state media. Reuters. 23 June 2020.
- 144.Landau, Elizabeth. Deep Space Atomic Clock. NASA. 27 April 2015.
- 145.Northon, Karen. NASA Technology Missions Launch on SpaceX Falcon Heavy. NASA. 25 June 2019.
- 146.NASA Jet Propulsion Laboratory (JPL). NASA Activates Deep Space Atomic Clock.
- 147.Hartono, Naomi. Working Overtime: NASA's Deep Space Atomic Clock Completes Mission. NASA. 1 October 2021.
- 148.DARPA Aims for More Accurate Atomic Clock to Replace GPS. The Defense Post. 1 February 2022.
- 149.DARPA to launch programme for creating optical atomic clocks. Airforce Technology. 21 January 2022.
- 150.Michael A. Lombardi, "How Accurate is a Radio Controlled Clock?", , National Institute of Standards and Technology, 2010.
- 151.lombardi. Radio Station WWV. NIST. 24 September 2009.
- 152.Chen, Sophia. These Physicists Watched a Clock Tick for 14 Years Straight. Wired. 1059-1028.
- 153.Bothwell, Tobias. Resolving the gravitational redshift across a millimetre-scale atomic sample. Nature. 602. 7897. 420–424. 2022. 10.1038/s41586-021-04349-7.
- 154.sarah.henderson@nist.gov. JILA Atomic Clocks Measure Einstein's General Relativity at Millimeter Scale. NIST. 16 February 2022.
- 155.An Ultra-Precise Clock Shows How to Link the Quantum World With Gravity. Quanta Magazine. 25 October 2021.
- 156.mark.esser@nist.gov. Keeping Time at NIST. NIST. 18 June 2020.
- 157.TimeChainZ – Regulatory Reporting For High-Frequency Trading. www.chainzy.com.
- 158.Geng, Yilong. Exploiting a Natural Network Effect for Scalable, Fine-grained Clock Synchronization. 81–94. 2018. 978-1-939133-01-4.
- 159.Koller, S. B. Transportable Optical Lattice Clock with Uncertainty. Physical Review Letters. 118. 7. 13 February 2017. 0031-9007.
- 160.BIPM Time Dept database. International Bureau of Weights and Measures.
References
Citations
References
Each reference names the institution holding it, so a reader may go to the document itself.
institutional register
Bibliothèque nationale de France authority file 11980310nBibliothèque nationale de France
Partially resolvedinstitutional register
GND (German National Library) authority file 4259141-7GND (German National Library)
Partially resolvedinstitutional register
Internet Archive holdings naming atomic clockInternet Archive
Partially resolvedinstitutional register
Library of Congress authority file sh85009316Library of Congress
Partially resolvedreference work
Partially resolvedinstitutional register
Wikidata, structured authority record Q227467: atomic clockWikimedia Foundation
Unverified
The Encyclopedia exists whether or not anything is for sale. Corrections are recorded rather than overwritten, and every version of this record is kept. Published 14 August 2026.
Elsewhere in Clocks
110 published records in this field, each with its sources named.
- Astronomical clock in MessinaTerminology
- astronomical clock of BesançonTerminology
- Astronomische Uhr, Paulusdom, MünsterTerminology
- Atmos clockTerminology
- AudichronTerminology
- automaton clockTerminology
- Beauvais astronomical clockTerminology
- binary clockTerminology
Best supported in this field
For owners
Own an object connected with atomic clock?
A specialist will read what you send and tell you what the house can establish, what it cannot, and whether the object is suited to sale. There is no charge and no obligation. The object stays with you throughout; nothing is shipped to us unless it is arranged in writing beforehand.