Dilution refrigerator
A 3 He/ 4 He dilution refrigerator, or simply dilution refrigerator, is a cryogenic device that provides continuous cooling to temperatures as low as 2 mK, with no moving parts in the low-temperature region. The cooling power is provided by the heat of mixing of the helium-3 and helium-4 isotopes. • Illustration — Phase diagram of liquid 3 He– 4 He mixtures showing the phase separation The dilution refrigerator was first proposed by Heinz London in the early 1950s, and was experimentally realized in 1964 in the Kamerlingh Onnes Laboratorium at Leiden University.
Dilution refrigerator

Onri Jay Benally · CC BY-SA 2.0
- Field
- scientific instrument
Reference Check
Propose documentary evidence for Dilution refrigerator. A contribution is never written directly as fact: identity, source, rights and evidence gates still decide.
Sign in to contribute
World of VALÉORINE
Documentary connections
Only confirmed graph relationships appear here. Images are shown only when their identity and reuse rights both pass the documentary gate.
Documentary evidence
Documentary basis
Authority files
wikidata · Q229468 · wikipedia · Dilution refrigerator
In this article
Wet dilution refrigerators
Wet dilution refrigerators
In the classic dilution refrigerator (known as a wet dilution refrigerator), the 3 He is precooled and purified by liquid nitrogen at 77 K and a 4 He bath at 4.2 K. Next, the 3 He enters a vacuum chamber where it is further cooled to a temperature of 1.2–1.5 K by the 1 K bath, a vacuum-pumped 4 He bath (as decreasing the pressure of the helium reservoir depresses its boiling point). The 1 K bath liquefies the 3 He gas and removes the heat of condensation. The 3 He then enters the main impedance, a capillary with a large flow resistance. It is cooled by the still (described below) to a temperature 500–700 mK. Subsequently, the 3 He flows through a secondary impedance and one side of a set of counterflow heat exchangers where it is cooled by a cold flow of 3 He. Finally, the pure 3 He enters the mixing chamber, the coldest area of the device. In the mixing chamber, two phases of the 3 He– 4 He mixture, the concentrated phase (practically 100% 3 He) and the dilute phase (about 6.6% 3 He and 93.4% 4 He), are in equilibrium and separated by a phase boundary. Inside the chamber, the 3 He is diluted as it flows from the concentrated phase through the phase boundary into the dilute phase. The heat necessary for the dilution is the useful cooling power of the refrigerator, as the process of moving the 3 He through the phase boundary is endothermic and removes heat from the mixing chamber environment. The 3 He then leaves the mixing chamber in the dilute phase. On the dilute side and in the still the 3 He flows through superfluid 4 He which is at rest. The 3 He is driven through the dilute channel by a pressure gradient just like any other viscous fluid. On its way up, the cold, dilute 3 He cools the downward flowing concentrated 3 He via the heat exchangers and enters the still. The pressure in the still is kept low (about 10 Pa) by the pumps at room temperature. The vapor in the still is practically pure 3 He, which has a much higher partial pressure than 4 He at 500–700 mK. Heat is supplied to the still to maintain a steady flow of 3 He. The pumps compress the 3 He to a pressure of a few hundred millibar and feed it back into the cryostat, completing the cycle.
Dry dilution refrigerators
Dry dilution refrigerators
Modern dilution refrigerators (known as dry dilution refrigerators) can precool the 3 He with a cryocooler in place of liquid nitrogen, liquid helium, and a 1 K bath. No external supply of cryogenic liquids is needed in these "dry cryostats" and operation can be highly automated. However, dry cryostats have high energy requirements and are subject to mechanical vibrations, such as those produced by pulse tube refrigerators. The first experimental machines were built in the 1990s, when (commercial) cryocoolers became available, capable of reaching a temperature lower than that of liquid helium and having sufficient cooling power (on the order of 1 Watt at 4.2 K). Pulse tube coolers are commonly used cryocoolers in dry dilution refrigerators. Dry dilution refrigerators generally follow one of two designs. One design incorporates an inner vacuum can, which is used to initially precool the machine from room temperature down to the base temperature of the pulse tube cooler (using heat-exchange gas). However, every time the refrigerator is cooled down, a vacuum seal that holds at cryogenic temperatures needs to be made, and low temperature vacuum feed-throughs must be used for the experimental wiring. The other design is more demanding to realize, requiring heat switches that are necessary for precooling, but no inner vacuum can is needed, greatly reducing the complexity of the experimental wiring.
Cooling power
Cooling power
The cooling power (in watts) at the mixing chamber is approximately given by • \dot{Q}_m\;[\text{W}] = \left(\dot{n}_3\;[\text{mol/s}]\right)\left(95(T_m\;[\text{K}])^2 - 11(T_i\;[\text{K}])^2\right) where \dot n_3 is the 3 He molar circulation rate, T m is the mixing-chamber temperature, and T i the temperature of the 3 He entering the mixing chamber. There will only be useful cooling when • T_i This sets a maximum temperature of the last heat exchanger, as above this all cooling power is used up only cooling the incident 3 He. Inside of a mixing chamber there is negligible thermal resistance between the pure and dilute phases, T_i \approx T_m. and the cooling power reduces to • \dot{Q}_m\;[\text{W}] = 84\left(\dot{n}_3\;[\text{mol/s}]\right)(T\;[\text{K}])^2. A low T m can only be reached if T i is low. In dilution refrigerators, T i is reduced by using heat exchangers as shown in the schematic diagram of the low-temperature region above. However, at very low temperatures this becomes more and more difficult due to the so-called Kapitza resistance. This is a heat resistance at the surface between the helium liquids and the solid body of the heat exchanger. It is inversely proportional to T 4 and the heat-exchanging surface area A. In other words: to get the same heat resistance one needs to increase the surface by a factor 10,000 if the temperature reduces by a factor 10. In order to get a low thermal resistance at low temperatures (below about 30 mK), a large surface area is needed. The lower the temperature, the larger the area. In practice, one uses very fine silver powder.
Limitations
Limitations
There is no fundamental limiting low temperature of dilution refrigerators. Yet the temperature range is limited to about 2 mK for practical reasons. At very low temperatures, both the viscosity and the thermal conductivity of the circulating fluid become larger if the temperature is lowered. To reduce the viscous heating, the diameters of the inlet and outlet tubes of the mixing chamber must go as T, and to get low heat flow the lengths of the tubes should go as T. That means that, to reduce the temperature by a factor 2, one needs to increase the diameter by a factor of 8 and the length by a factor of 256. Hence the volume should be increased by a factor of 2 14 = 16,384. In other words: every cm 3 at 2 mK would become 16,384 cm 3 at 1 mK. The machines would become very big and very expensive. There is a powerful alternative for cooling below 2 mK: nuclear demagnetization refrigeration.

A millikelvin range large frame dilution refrigerator, with high bandwidth ribbon-like cables installed and the wiring chassis shown in the case (translucent). Available in ~8K resolution. Downloadable under a Creative Commons license.
OJB Quantum

A high bandwidth millikelvin range large frame dilution refrigerator, with high bandwidth ribbon-like cables installed and the wiring chassis shown (case removed). Available in ~8K resolution. Downloadable under a Creative Commons license.
OJB Quantum
Theory of operation
The refrigeration process uses a mixture of the two stable isotopes of helium: helium-3 and helium-4. When cooled below approximately 870 millikelvins, the mixture undergoes spontaneous phase separation to form a 3 He-rich phase (the concentrated phase) and a 3 He-poor phase (the dilute phase). As shown in the phase diagram, at very low temperatures the concentrated phase is essentially pure 3 He, while the dilute phase contains about 6.6% 3 He and 93.4% 4 He. The working fluid is 3 He, which is circulated by vacuum pumps at room temperature. The 3 He enters the cryostat at a pressure of a few hundred millibar. • Illustration — Schematic diagram of a wet 3 He/ 4 He dilution refrigerator without the outer vacuum shield • Illustration — Schematic diagram of a standard, or wet, dilution refrigerator • Illustration — Schematic diagram of the low-temperature part of a dilution refrigerator • Illustration — The inside of a wet Oxford Instruments helium dilution refrigerator, with the vacuum cans removed • Illustration — Gas control system for a helium dilution refrigerator • Illustration — Schematic diagram of a cryogen-free, or dry, dilution refrigerator precooled by a two-stage pulse tube refrigerator, indicated by the dotted rectangle
Primary material
Documents and archives
institutional register
- Internet Archive holdings naming Dilution refrigerator
General reference · Internet Archive
reference work
- “Dilution refrigerator”, English Wikipedia, consulted as further reading
Reputable secondary · Wikipedia
authority record
- Wikidata, structured authority record Q229468: Dilution refrigerator
General reference · Wikidata
Text attribution
Licensing
Text attribution
Part of the biographical narrative on this page reuses licensed material. Its origin, revision and licence are recorded here.
The biographical narrative on this page is based on the Wikipedia article Dilution refrigerator, revision 1375073377 (EN edition), by its contributors. VALÉORINE has edited that text and built its own documentary record around it. The reused material is available under CC BY-SA 4.0, and this page's reuse of it is offered under the same licence. Everything else on this page — the chronology, the holdings, the evidence, the plates and the connections — is VALÉORINE's own record. Sources and licences.
Notes from the source article
Cited by Wikipedia
Notes from the source article
These works are cited by the source article, in its own numbering. They are recorded as its citations, not as sources VALÉORINE has verified.
- 1.Lounasmaa, O. V. Experimental Principles and Methods Below 1 K. Academic Press. 316. 1974. 978-0-12-455950-9.
- 2.Pobell, Frank. Matter and Methods at Low Temperatures. Springer-Verlag. 461. 2007. 978-3-540-46360-3.
- 3.Das, P. Low Temperature Physics LT9. 1253. 1965. 978-1-4899-6217-1.
- 4.de Waele, A.Th.A.M. Progress in Low Temperature Physics, Volume 13. Elsevier. 167–218. 1991. 978-0-08-087308-4.
- 5.de Waele, A. T. A. M. Basic Operation of Cryocoolers and Related Thermal Machines. Journal of Low Temperature Physics. 164. 5–6. 179–236. 2011. 10.1007/s10909-011-0373-x.
- 6.Uhlig, K. 3 He/ 4 He Dilution refrigerator precooled by Gifford-McMahon refrigerator. Cryogenics. 37. 5. 279. 1997. 10.1016/S0011-2275(97)00026-X.
References
Citations
References
Each reference names the institution holding it, so a reader may go to the document itself.
institutional register
Internet Archive holdings naming Dilution refrigeratorInternet Archive
Secondary witnessreference work
Secondary witnessauthority record
General reference
The Encyclopedia exists whether or not anything is for sale. Corrections are recorded rather than overwritten, and every version of this record is kept. Published 14 August 2026.
Elsewhere in Scientific instruments
736 published records in this field, each with its sources named.
- dichroscopeTerminology
- difference engineTerminology
- Digital sundialTerminology
- Digitized Sky SurveyTerminology
- Diviner Lunar Radiometer ExperimentTerminology
- Dobson ozone spectrophotometerTerminology
- Dobsonian telescopeTerminology
- Doppler Orbitography and Radiopositioning Integrated by SatelliteTerminology
Best supported in this field
For owners
Own an object connected with Dilution refrigerator?
A specialist will read what you send and tell you what the house can establish, what it cannot, and whether the object is suited to sale. There is no charge and no obligation. The object stays with you throughout; nothing is shipped to us unless it is arranged in writing beforehand.